<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//TaxonX//DTD Taxonomic Treatment Publishing DTD v0 20100105//EN" "../../nlm/tax-treatment-NS0.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:tp="http://www.plazi.org/taxpub" article-type="research-article" dtd-version="3.0" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">87</journal-id>
      <journal-id journal-id-type="index">urn:lsid:arphahub.com:pub:A116C711-4C18-5A38-8F1E-5E97753A8A64</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Folia Medica</journal-title>
        <abbrev-journal-title xml:lang="en">FM</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0204-8043</issn>
      <issn pub-type="epub">1314-2143</issn>
      <publisher>
        <publisher-name>Plovdiv Medical University</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3897/folmed.65.e100965</article-id>
      <article-id pub-id-type="publisher-id">100965</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Article</subject>
        </subj-group>
        <subj-group subj-group-type="scientific_subject">
          <subject>Anesthesiology</subject>
          <subject>Metabolic disorders</subject>
          <subject>Nutrition</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Comparative characteristics of some methods for estimating energy expenditure in critically ill mechanically ventilated patients</article-title>
      </title-group>
      <contrib-group content-type="authors">
        <contrib contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Nikolova</surname>
            <given-names>Siyana</given-names>
          </name>
          <email xlink:type="simple">siyana.n.k@gmail.com</email>
          <uri content-type="orcid">https://orcid.org/0000-0001-5269-5770</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Kyosebekirov</surname>
            <given-names>Emral</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Mitkovski</surname>
            <given-names>Emil</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Kazakov</surname>
            <given-names>Dimitar</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0002-6476-0098</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Stoilov</surname>
            <given-names>Valentin</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0001-5805-0906</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Pavlov</surname>
            <given-names>Georgi</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0002-9286-3174</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Stefanov</surname>
            <given-names>Chavdar</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="A1">
        <label>1</label>
        <addr-line content-type="verbatim">Department of Anesthesiology, Emergency and Intensive Care Medicine, Faculty of Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria</addr-line>
        <institution>Medical University of Plovdiv</institution>
        <addr-line content-type="city">Plovdiv</addr-line>
        <country>Bulgaria</country>
      </aff>
      <author-notes>
        <fn fn-type="corresp">
          <p>Corresponding author: Siyana Nikolova, Department of Anesthesiology, Emergency and Intensive Care Medicine, Faculty of Medicine, Medical University of Plovdiv, 15A Vassil Aprilov Blvd., 4002 Plovdiv, Bulgaria; Email: <email xlink:type="simple">siyana.n.k@gmail.com</email></p>
        </fn>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2023</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>31</day>
        <month>12</month>
        <year>2023</year>
      </pub-date>
      <volume>65</volume>
      <issue>6</issue>
      <fpage>909</fpage>
      <lpage>914</lpage>
      <uri content-type="arpha" xlink:href="http://openbiodiv.net/F965C4B7-7888-57FE-AF4C-2C229CBF182B">F965C4B7-7888-57FE-AF4C-2C229CBF182B</uri>
      <history>
        <date date-type="received">
          <day>24</day>
          <month>01</month>
          <year>2023</year>
        </date>
        <date date-type="accepted">
          <day>16</day>
          <month>03</month>
          <year>2023</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>Siyana Nikolova, Emral Kyosebekirov, Emil Mitkovski, Dimitar Kazakov, Valentin Stoilov, Georgi Pavlov, Chavdar Stefanov</copyright-statement>
        <license license-type="creative-commons-attribution" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <abstract>
        <label>Abstract</label>
        <p><bold>Aim</bold>: To compare the energy expenditure (EE) assessed by ventilator-derived carbon dioxide production (EE–VCO<sub>2</sub>-ventilator) and the energy expenditure calculated from six predictive equations with the gold standard energy expenditure measured with indirect calorimetry (IC) in mechanically ventilated patients.</p>
        <p><bold>Materials and methods</bold>: This is a prospective, non-randomized, one-month study which included six mechanically ventilated patients with FiO<sub>2</sub> &lt;60% and PEEP &lt;10 mbar. Thirty-minute measurements were taken using a Cosmed Q-NRG+ metabolic monitor. The average ventilator-derived VCO<sub>2</sub> from the Drager Evita Infinity V500 respirator (VʹCO<sub>2</sub>, ml/min) was calculated for the same period. The IC-measured EE (MEE-IC) was compared with EE–VCO<sub>2</sub>-ventilator by a formula proposed in ESPEN (8.19×VCO<sub>2</sub>) and with six predictive equations.</p>
        <p><bold>Results</bold>: Mean MEE-IC was 1650±365 kcal. Mean measured EE–VCO<sub>2</sub>-ventilator was 1669±340 kcal. A statistically nonsignificant difference was found between the two measurements (<italic>p</italic>=0.84, correlation coefficient 0.98). Of the predictive equations we compared, the best correlation to the reference method was the Penn State 3 with mean EE of 1679±356 (<italic>p</italic>=0.81, correlation coefficient of 0.78).</p>
        <p><bold>Conclusions</bold>: In critically ill mechanically ventilated patients, the assessment of EE based on a ventilator-derived VCO<sub>2</sub> is an alternative to IC and is more accurate than most predictive equations.</p>
      </abstract>
      <kwd-group>
        <label>Keywords</label>
        <kwd>calories</kwd>
        <kwd>energy metabolism</kwd>
        <kwd>indirect calorimetry</kwd>
        <kwd>predictive equations</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="Introduction" id="SECID0E2F">
      <title>Introduction</title>
      <p>Nutritional support is an integral part of intensive care. In practice, caloric needs are estimated using both measured energy expenditure (MEE) and a fixed sum of calories based on predictive equations.<sup>[<xref ref-type="bibr" rid="B1 B2 B3 B4">1–4</xref>]</sup> Energy expenditure (EE) during the stay in the ICU is known to be dynamic, influenced by body temperature<sup>[<xref ref-type="bibr" rid="B5">5</xref>]</sup>, nutritional support<sup>[<xref ref-type="bibr" rid="B6">6</xref>]</sup>, presence of sepsis<sup>[<xref ref-type="bibr" rid="B7">7</xref>]</sup>, level of sedation<sup>[<xref ref-type="bibr" rid="B8">8</xref>]</sup>, and physiotherapy<sup>[<xref ref-type="bibr" rid="B9">9</xref>]</sup>. The only measurement of EE using techniques such as indirect calorimetry (IC) can accurately estimate the energy requirements of critically ill patients (CIP).<sup>[<xref ref-type="bibr" rid="B10">10</xref>]</sup> Measurement of EE contributes to the prevention of overfeeding during the early phase of intensive care and underfeeding during the late phase, both of which are associated with increased mortality.<sup>[<xref ref-type="bibr" rid="B11 B12 B13">11–13</xref>]</sup></p>
      <p>EE can be accurately calculated with IC which measures oxygen consumption (VO<sub>2</sub>) and carbon dioxide production (VCO<sub>2</sub>) from the respiratory mixture.<sup>[<xref ref-type="bibr" rid="B14">14</xref>,15]</sup> EE can then be calculated using Weir’s abbreviated formula<sup>[<xref ref-type="bibr" rid="B16">16</xref>]</sup>:</p>
      <p>ЕE kcal/day = 3.941×VO<sub>2</sub> (L/min) + 1.11×VCO<sub>2</sub> (L/min)×1440</p>
      <p>Although IC is the reference method for EE assessment<sup>[<xref ref-type="bibr" rid="B17">17</xref>]</sup>, metabolic monitoring is often unavailable, implementation of IC is time- and resource-consuming, and even in a prospective clinical trial study, IC is performed effectively in only 40% of patients<sup>[<xref ref-type="bibr" rid="B18">18</xref>]</sup>. Therefore, daily assessment of EE by IC is difficult to implement but may be important, as EE is known to vary significantly over time because of changes in metabolic rate.<sup>[<xref ref-type="bibr" rid="B19 B20 B21">19–21</xref>]</sup></p>
      <p>In CIPs, the EE calculated by predictive equations shows a significant difference from MEE measured by IC.<sup>[<xref ref-type="bibr" rid="B22">22</xref>]</sup> More than 200 predictive equations have been developed, and there is no consensus on which of them should be used in routine practice. It is best to use specific equations in patients like the reference population from which the equation was derived. Equations that only consider static variables such as height, age, weight, and gender and do not account for metabolic changes are proverbially inaccurate in estimating the caloric needs of critically ill patients. If equations are to be used to calculate the EE in critically ill patients, the Penn State University equations are the best choice because they include some dynamic parameters, such as body temperature and minute ventilation.<sup>[<xref ref-type="bibr" rid="B23">23</xref>,24]</sup></p>
      <p>An alternative method is the assessment of EE based on ventilator-derived VCO<sub>2</sub>. Modern mechanical ventilators can measure VCO<sub>2</sub> continuously, making the method practical and allowing long-term monitoring.<sup>[<xref ref-type="bibr" rid="B25 B26 B27">25–27</xref>]</sup> Since the respirator cannot measure VO<sub>2</sub>, the Weir’s equation is adjusted using a respiratory quotient (RQ) to calculate EE as follows:</p>
      <p>ЕE kcal/day = (3.941×VCO<sub>2</sub>/RQ + 1.11×VCO<sub>2</sub>)×1440</p>
      <p>To date, several studies have examined the EE–VCO<sub>2</sub>-ventilator with mixed results.<sup>[25-27,31-33]</sup></p>
    </sec>
    <sec sec-type="Aim" id="SECID0ESCAC">
      <title>Aim</title>
      <p>The aim of the present study was to compare the EE–VCO<sub>2</sub>-ventilator in mechanically ventilated patients calculated by the formula (8.19×VCO<sub>2</sub>)‌<sup>[<xref ref-type="bibr" rid="B2">2</xref>,25]</sup>, as well as EE from six predictive equations with a reference method MEE-IC.</p>
    </sec>
    <sec sec-type="materials|methods" id="SECID0EDDAC">
      <title>Materials and methods</title>
      <p>This is a prospective, non-randomized study conducted over a period of one month. It included six mechanically ventilated patients who were hospitalized and treated in the ICU of the Clinic of Anesthesiology and Intensive Care at St George University Hospital in Plovdiv. Thirty 30-minute measurements were taken using a Cosmed Q-NRG+ metabolic monitor. Three to seven measurements per patient were performed on different days﻿. The sample of patients was random. They were between 52 and 62 years old, two men and four women. Two patients with polytrauma, one of them with a dominant thoracic trauma, with a thoracic drain placed, but with a reported leak from mechanical ventilation of less than 8%. The remaining patients had subdural hematoma or intracerebral hemorrhage. In 8 of the measurements, the patients were conscious and evaluated by GCS, with an average score of 12 points. In the rest of the measurements, the patients were sedated and assessed according to the Ramsay sedation scale, with an average score of 3-4 points. One of the patients was connected to the ventilator with a tracheostomy cannula, the others were connected with endotracheal tubes. In 14 of the measurements, the patients were on pressure support ventilation, in the remaining measurements, they were in a combined mode - controlled plus supported ventilation, the average measured minute ventilation was 8 liters, and the average leak from mechanical ventilation was 4%. Only in three measurements did the patients receive vasopressors but continued to have mean arterial pressures greater than 65 mmHg; otherwise, all patients had stable hemodynamics. The calorimeter was calibrated according to the manufacturer’s recommendations with a routine Pneumotach test before each measurement, as well as a monthly Gas Analyzer test and a Blower test. Patients’ inclusion criteria were stable condition at least 30 minutes before measurement, normocapnia, ventilation with FiO<sub>2</sub> &lt;60% and PEEP &lt;10 mbar. The average CO<sub>2</sub> production from the Drager Evita Infinity V500 respirator (VʹCO<sub>2</sub>, ml/min) was tracked for the same period. The МEE-IC was compared with EE–VCO<sub>2</sub>-ventilator calculated by this formula - 8.19×VCO<sub>2</sub><sup>[<xref ref-type="bibr" rid="B2">2</xref>,25]</sup> as well as with EE from six predictive equations: the Harris-Benedict<sup>[<xref ref-type="bibr" rid="B28">28</xref>]</sup>, the Mifflin-St. Jeor<sup>[<xref ref-type="bibr" rid="B29">29</xref>]</sup>, the equations of Penn State University<sup>[<xref ref-type="bibr" rid="B30">30</xref>]</sup>, from the proposed body weight formulas of ASPEN<sup>[<xref ref-type="bibr" rid="B4">4</xref>]</sup> 12–25 kcal/kg/d and ESPEN<sup>[<xref ref-type="bibr" rid="B2">2</xref>]</sup> 20–25 kcal/kg/d, 20 kcal/kg/d, and 25 kcal/kg/d were included in the comparison. The average minute ventilation for the calorimetry period as well as the highest body temperature recorded during the last 24 hours was taken to calculate the Penn State University equations. The mean EE of the different methods was calculated. The MEE by IC is the method used as a reference to which the results achieved by all other prediction methods are compared. The mean difference and the standard deviation between each of the calculation methods and the reference one were presented as ΔcEE-mEE. Student’s <italic>t</italic>-test was applied to compare paired data. Correlations were calculated using the Pearson’s test and the results were presented as <italic>r.</italic></p>
    </sec>
    <sec sec-type="Results" id="SECID0E6EAC">
      <title>Results</title>
      <p>The average МEЕ–IC was 1650 kcal. The mean measured EЕ–VCO<sub>2</sub>-ventilator was 1669 kcal. A statistically nonsignificant difference was found between the two measurements (<italic>p</italic>=0.84, <italic>r</italic>=0.98), the mean difference to the reference method and standard deviation (19±68). Of the predictive equations we compared, the lowest difference to the reference method was calculated with the Penn State 3 (30±236), mean EE of 1679 (<italic>p</italic>=0.81, <italic>r</italic>=0.78). The obtained results are presented in <bold>Table <xref ref-type="table" rid="T1">1</xref></bold>.</p>
      <table-wrap id="T1" position="float" orientation="portrait">
        <label>Table 1.</label>
        <caption>
          <p>Comparative characteristics of different methods for estimating energy expenditure</p>
        </caption>
        <table id="TID0ELHAE" rules="all">
          <tbody>
            <tr>
              <td rowspan="1" colspan="1">
                <bold>Measurement</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Mean</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Mean ΔcEE-mEE ± SD</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold><italic>p</italic>-value</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>
                  <italic>r</italic>
                </bold>
              </td>
            </tr>
            <tr>
              <td rowspan="1" colspan="5">VCO<sub>2</sub> (ml/min)</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">IC</td>
              <td rowspan="1" colspan="1">194</td>
              <td rowspan="1" colspan="1"/>
              <td rowspan="1" colspan="1"/>
              <td rowspan="1" colspan="1"/>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Ventilator</td>
              <td rowspan="1" colspan="1">204</td>
              <td rowspan="1" colspan="1"/>
              <td rowspan="1" colspan="1">0.44</td>
              <td rowspan="1" colspan="1">0.91</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="5">Energy expenditure (kcal/d)</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">IC</td>
              <td rowspan="1" colspan="1">1650</td>
              <td rowspan="1" colspan="1"/>
              <td rowspan="1" colspan="1"/>
              <td rowspan="1" colspan="1"/>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">VCO<sub>2</sub>-ventilator</td>
              <td rowspan="1" colspan="1">1669</td>
              <td rowspan="1" colspan="1">19±68</td>
              <td rowspan="1" colspan="1">0.84</td>
              <td rowspan="1" colspan="1">0.98</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Harris-Benedict</td>
              <td rowspan="1" colspan="1">1663</td>
              <td rowspan="1" colspan="1">−143±68</td>
              <td rowspan="1" colspan="1">0.12</td>
              <td rowspan="1" colspan="1">0.72</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">ESPEN/ASPEN (20 kcal/kg/d)</td>
              <td rowspan="1" colspan="1">1577</td>
              <td rowspan="1" colspan="1">−73±279</td>
              <td rowspan="1" colspan="1">0.41</td>
              <td rowspan="1" colspan="1">0.65</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">ESPEN/ASPEN (25 kcal/kg/d)</td>
              <td rowspan="1" colspan="1">1971</td>
              <td rowspan="1" colspan="1">321±288</td>
              <td rowspan="1" colspan="1">0.002</td>
              <td rowspan="1" colspan="1">0.65</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Mifflin-St. Jeor</td>
              <td rowspan="1" colspan="1">1528</td>
              <td rowspan="1" colspan="1">−121±204</td>
              <td rowspan="1" colspan="1">0.23</td>
              <td rowspan="1" colspan="1">0.83</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Penn State 1</td>
              <td rowspan="1" colspan="1">1754</td>
              <td rowspan="1" colspan="1">104±265</td>
              <td rowspan="1" colspan="1">0.31</td>
              <td rowspan="1" colspan="1">0.70</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Penn State 2</td>
              <td rowspan="1" colspan="1">1593</td>
              <td rowspan="1" colspan="1">−57±284</td>
              <td rowspan="1" colspan="1">0.51</td>
              <td rowspan="1" colspan="1">0.63</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">Penn State 3</td>
              <td rowspan="1" colspan="1">1679</td>
              <td rowspan="1" colspan="1">30±236</td>
              <td rowspan="1" colspan="1">0.81</td>
              <td rowspan="1" colspan="1">0.78</td>
            </tr>
          </tbody>
        </table>
        <table-wrap-foot>
          <fn>
            <p>ΔcEE-mEE: the difference between measured energy expenditure by indirect calorimetry and calculated energy expenditure by predictive equations, as well as by ventilator-derived carbon dioxide production; VCO<sub>2</sub>: the carbon dioxide production; ESPEN: European Society for Clinical Nutrition and Metabolism; ASPEN: American Society for Parenteral and Enteral Nutrition; <italic>r</italic>: correlation coefficient.</p>
          </fn>
        </table-wrap-foot>
      </table-wrap>
    </sec>
    <sec sec-type="Discussion" id="SECID0EVFAC">
      <title>Discussion</title>
      <p>The present prospective study in mechanically ventilated patients confirms the concept that EE can be accurately estimated by ventilator-derived VCO<sub>2</sub>. Moreover, it shows that this method is more accurate than most predictive equations, especially those using only static parameters. However, the Penn State 3 equation is a good choice if predictive equations are to be used because it includes variables (minute ventilation and body temperature).</p>
      <p>The results of our study are consistent with those of Stepel et al., who, in a sufficient sample size (84 patients on mechanical ventilation, a heterogeneous group), compared МEE from a 24-h IC, EP–VCO<sub>2</sub>-ventilator as well as EE–VCO<sub>2</sub> from a metabolic monitor. They found that the EE–VCO<sub>2</sub>-ventilator was acceptably accurate and more precise than predictive equations.<sup>[<xref ref-type="bibr" rid="B25">25</xref>]</sup> Based on the study, ESPEN<sup>[<xref ref-type="bibr" rid="B2">2</xref>]</sup> in 2018 recommended that in the absence of IC, measurement of EE should be carried out by using the carbon dioxide production obtained from the ventilator according to the formula proposed by Stepel: EE = VCO<sub>2</sub>×8.19.<sup>[<xref ref-type="bibr" rid="B25">25</xref>]</sup> In another study which makes a comparison of a different method of energy expenditure in COVID-19 mechanically ventilated patients, Saseedharan et al.<sup>[<xref ref-type="bibr" rid="B31">31</xref>]</sup> concludes that the EE estimated by ventilator-derived carbon dioxide correlated better with IC values than the energy expenditure derived from weight-based calculations.</p>
      <p>One of the latest studies, Linder et al.<sup>[<xref ref-type="bibr" rid="B32">32</xref>]</sup> published on 7 January 2023, shows that median measured resting EE was significantly higher in the critically ill (1457 kcal/d) versus the healthy cohort (1351 kcal/d), with low predictive equations accuracy rates (21% to 49%), showing again the need to be more accurate.</p>
      <p>Rousing et al.<sup>[<xref ref-type="bibr" rid="B26">26</xref>]</sup> confirmed the lack of accuracy of predictive equations and indicated the use of VCO<sub>2</sub> as a more accurate alternative for EE estimation. The study confirms that using only VCO<sub>2</sub> without VO<sub>2</sub> is a sensitive method for determining EE. This study’s shortcoming is using VCO<sub>2</sub> only from the calorimeter and not from the ventilator. Koekkoek et al.<sup>[<xref ref-type="bibr" rid="B27">27</xref>]</sup> came out with a controversial opinion: EE–VCO<sub>2</sub>-ventilator compared to EE–IC overestimates actual energy expenditure, and predictive equations, although inaccurate, may even predict EE better compared to the VCO<sub>2</sub> method. In this study, in contrast to Stepel’s study<sup>[<xref ref-type="bibr" rid="B25">25</xref>]</sup>, a greater difference in reported VCO<sub>2</sub> from the ventilator compared with VCO<sub>2</sub> from the metabolic monitor was noted, which appears to be the cause of an overestimation of EE–VCO<sub>2</sub>-ventilator versus EE–IC. In the study by Koekkoek et al.<sup>[<xref ref-type="bibr" rid="B27">27</xref>]</sup>, the authors themselves indicated that the significant bias and low levels of accuracy in the study could be attributed to inaccuracy in VCO<sub>2</sub> measurement from the ventilator (calibration error, patient-ventilator desynchronization), or inaccuracy of the metabolic monitor (error during calibration, large variability (&gt;10%) of VCO<sub>2</sub> and VO<sub>2</sub> during measurement. Another reason for the difference between the two studies was a difference in the duration of the measurements, which was 24 hours in the study by Stapel et al.<sup>[<xref ref-type="bibr" rid="B25">25</xref>]</sup> and 6 times per day for 10 minutes each in the study by Koekkoek et al.<sup>[<xref ref-type="bibr" rid="B27">27</xref>]</sup></p>
      <p>﻿Briassoulis et al.<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup> conclude that VCO<sub>2</sub>-derived predicted EE cannot be recommended as an alternative to EE measured by IC in mechanically ventilated children. They stated that a new generation of user-friendly, cost-effective calorimeters incorporated into the ventilators’ hardware and software is a one-way street to overcome the current limitations in reliably measuring real-time EE in an intensive care setting. To some extent, we agree with that. IC remains the gold standard method to measure EE. Maybe, this new generation of calorimeters is the future, but they are not widespread in the world, also results of measurements with them will be discussed first. So, while IC is still a time- and resource-consuming process, we need an alternative. In this study, calculated EE by predictive equations in children is not included.</p>
      <p>A disadvantage of our study is the small number of patients, 6 patients who had a total of 30 measurements on different days, which can be a potential source of bias in the obtained results. Moreover, factors such as gender and age are not taken into consideration.</p>
    </sec>
    <sec sec-type="Conclusions" id="SECID0E2JAC">
      <title>Conclusions</title>
      <p>In critically ill patients on invasive mechanical ventilation, assessment of EЕ by analysis of CO<sub>2</sub> production by the ventilator is a reliable alternative. EE–VCO<sub>2</sub>-ventilator is more accurate than most predictive equations. Unlike indirect calorimetry, the method is easy to apply, convenient for long-term monitoring, does not take additional time and resources, and is not associated with additional disconnection of the patient from the respiratory circuit. The results of our study coincide with those of Stapel et al. Further research is needed to determine the applicability of the method in routine practice. If, however, it is necessary to use predictive equations in mechanically ventilated patients, the Penn State 3 equation is a good choice.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>﻿References</title>
      <ref id="B1">
        <mixed-citation xlink:type="simple">1. Singer P, Berger MM, Van den Berghe G, et al. ESPEN Guidelines on Parenteral Nutrition: Intensive care. Clin Nutr 2009; 28(4):387–400.</mixed-citation>
      </ref>
      <ref id="B2">
        <mixed-citation xlink:type="simple">2. Singer P, Blaser AR, Berger MM, et al. ESPEN guideline on clinical nutrition in the intensive care unit. Clin Nutr 2019; 38(1):48–79.</mixed-citation>
      </ref>
      <ref id="B3">
        <mixed-citation xlink:type="simple">3. McClave SA, Taylor BE, Martindale RG, et al. Guidelines for the provision and assessment of nutrition support therapy in the adult critically ill patient: Society of Critical Care Medicine (SCCM) and American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.). JPEN J Parenter Enteral Nutr 2016; 40(2):159–211.</mixed-citation>
      </ref>
      <ref id="B4">
        <mixed-citation xlink:type="simple">4. Compher C, Bingham AL, McCall M, et al. Guidelines for the provision of nutrition support therapy in the adult critically ill patient: The American Society for Parenteral and Enteral Nutrition. JPEN J Parenter Enteral Nutr 2022; 46(1):12–41.</mixed-citation>
      </ref>
      <ref id="B5">
        <mixed-citation xlink:type="simple">5. Bruder N, Raynal M, Pellissier D, et al. Influence of body temperature, with or without sedation, on energy expenditure in severe head-injured patients. Crit Care Med (Philadelphia) 1998; 26:568–72.</mixed-citation>
      </ref>
      <ref id="B6">
        <mixed-citation xlink:type="simple">6. Cankayali I, Demirag K, Kocabas S, et al. The effects of standard and branched chain amino acid enriched solutions on thermogenesis and energy expenditure in unconscious care patients. Clin Nutr 2004; 23(2):257–63.</mixed-citation>
      </ref>
      <ref id="B7">
        <mixed-citation xlink:type="simple">7. Kreyman G, Grosser S, Buggisch P, et al. Oxygen consumption and resting metabolic rate in sepsis, sepsis syndrome, and septic shock. Crit Care Med (Philadelphia) 1993; 21:1012–9.</mixed-citation>
      </ref>
      <ref id="B8">
        <mixed-citation xlink:type="simple">8. Terao Y, Miura K, Saito M, et al. Quantitative analysis of the relationship between sedation and resting energy expenditure in postoperative patients. Crit Care Med (Philadelphia) 2003; 31(3):830–3.</mixed-citation>
      </ref>
      <ref id="B9">
        <mixed-citation xlink:type="simple">9. Weissman C, Kemper M, Elwyn DH, et al. The energy expenditure of the mechanically ventilated critically ill patient: an analysis. Chest (Chicago) 1986; 89(2):254–9.</mixed-citation>
      </ref>
      <ref id="B10">
        <mixed-citation xlink:type="simple">10. Lev S, Cohen J, Singer P. Indirect calorimetry measurements in the ventilated critically ill patient: facts and controversies - the heat is on. Crit Care Clin (Philadelphia) 2010; 26(4):e1–9.</mixed-citation>
      </ref>
      <ref id="B11">
        <mixed-citation xlink:type="simple">11. Weijs P, Looijaard W, Beishuizen A, et al. Early high protein intake is associated with low mortality and energy overfeeding with high mortality in non-septic mechanically ventilated critically ill patients. Crit Care (London) 2014; 18(6):701.</mixed-citation>
      </ref>
      <ref id="B12">
        <mixed-citation xlink:type="simple">12. Singer P, Pichard C, Heidegger CP, et al. Considering energy deficit in the intensive care unit. Curr Opin Clin Nutr Metab Care (London) 2010; 13(2):170–6.</mixed-citation>
      </ref>
      <ref id="B13">
        <mixed-citation xlink:type="simple">13. Villet S, Chiolero RL, Bollmann MD, et al. Negative impact of hypocaloric feeding and energy balance on clinical outcome in ICU patients. Clin Nutr 2005; 24(4):502–9.</mixed-citation>
      </ref>
      <ref id="B14">
        <mixed-citation xlink:type="simple">14. Cooney RN, Frankenfield DC. Determining energy needs in critically ill patients: Equations or indirect calorimeters. Curr Opin Crit Care (Hagerstown) 2012; 18(2):174–7.</mixed-citation>
      </ref>
      <ref id="B15">
        <mixed-citation xlink:type="simple">15. Branson RD, Johannigman JA. The measurement of energy expenditure. Nutr Clin Pract (US) 2004; 19(6):622–36.</mixed-citation>
      </ref>
      <ref id="B16">
        <mixed-citation xlink:type="simple">16. Weir JB. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol (England) 1949; 109(1-2):1–9.</mixed-citation>
      </ref>
      <ref id="B17">
        <mixed-citation xlink:type="simple">17. Preiser JC, van Zanten AR, Berger MM, et al. Metabolic and nutritional support of critically ill patients: consensus and controversies. Crit Care (London) 2015; 19(1):35.</mixed-citation>
      </ref>
      <ref id="B18">
        <mixed-citation xlink:type="simple">18. De Waele E, Spapen H, Honoré PM, et al. Introducing a new generation indirect calorimeter for estimating energy requirements in adult intensive care unit patients: feasibility, practical considerations, and comparison with a mathematical equation. J Crit Care (US) 2013; 28(5):884.e1–e6.</mixed-citation>
      </ref>
      <ref id="B19">
        <mixed-citation xlink:type="simple">19. McClave SA, Martindale RG, Kiraly L. The use of indirect calorimetry in the intensive care unit. Curr Opin Clin Nutr Metab Care (London) 2013; 16(2):202–8.</mixed-citation>
      </ref>
      <ref id="B20">
        <mixed-citation xlink:type="simple">20. Berger MM, Pichard C. Best timing for energy provision during critical illness. Crit Care (London) 2012; 16(2):215.</mixed-citation>
      </ref>
      <ref id="B21">
        <mixed-citation xlink:type="simple">21. Preiser JC, Ichai C, Orban JC, et al. Metabolic response to the stress of critical illness. Br J Anaesth (London) 2014; 113(6):945–54.</mixed-citation>
      </ref>
      <ref id="B22">
        <mixed-citation xlink:type="simple">22. Zusman O, Kagan I, Bendavid I, et al. Predictive equations versus measured energy expenditure by indirect calorimetry: A retrospective validation. Clin Nutr (Edinburg, Scotland) 2019; 38(3):1206–10.</mixed-citation>
      </ref>
      <ref id="B23">
        <mixed-citation xlink:type="simple">23. Walker RN, Heuberger RA. Predictive equations for energy needs for the critically ill. Resp Care (Dallas) 2009; 54(4):509–21.</mixed-citation>
      </ref>
      <ref id="B24">
        <mixed-citation xlink:type="simple">24. Frankenfield DC, Coleman A, Alam S, et al. Analysis of estimation methods for resting metabolic rate in critically ill adults. JPEN J Parenter Enter Nutr (US) 2009; 33(1):27–36.</mixed-citation>
      </ref>
      <ref id="B25">
        <mixed-citation xlink:type="simple">25. Stapel SN, De Grooth HJ, Alimohamad H, et al. Ventilator-derived carbon dioxide production to assess energy expenditure in critically ill patients: Proof of concept. Crit Care (London) 2015; 19:370.</mixed-citation>
      </ref>
      <ref id="B26">
        <mixed-citation xlink:type="simple">26. Rousing ML, Hahn-Pedersen MH, Andreassen S, et al. Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO<sub>2</sub>-based indirect calorimetry. Ann Intensive Care (Heidelberg) 2016; 6(1):16.</mixed-citation>
      </ref>
      <ref id="B27">
        <mixed-citation xlink:type="simple">27. Koekkoek WAC, Xiaochen G, van Dijk D, et al. Resting energy expenditure by indirect calorimetry versus the ventilator-VCO<sub>2</sub> derived method in critically ill patients: The DREAM-VCO<sub>2</sub> prospective comparative study. Clin Nutr ESPEN (England) 2020; 39:137–43.</mixed-citation>
      </ref>
      <ref id="B28">
        <mixed-citation xlink:type="simple">28. Harris JA, Benedict FG. A biometric study of human basal metabolism. Proc Natl Acad Sci USA (Washington) 1918; 4(12):370–3.</mixed-citation>
      </ref>
      <ref id="B29">
        <mixed-citation xlink:type="simple">29. Muffin MD, St Jeor ST, Hill LA, et al. A new predictive equation for resting energy expenditure in healthy individuals. Am J Clin Nutr (US) 1990; 51(2):241–7.</mixed-citation>
      </ref>
      <ref id="B30">
        <mixed-citation xlink:type="simple">30. Frankenfield D, Smith JS, Cooney RN. Validation of 2 approaches to predicting resting metabolic rate in critically ill patients. JPEN J Parenter Enteral Nutr (US) 2004; 28(4):259–64.</mixed-citation>
      </ref>
      <ref id="B31">
        <mixed-citation xlink:type="simple">31. Saseedharan S, Chada RR, Kadam V, et al. Energy expenditure in COVID-19 mechanically ventilated patients: A comparison of three methods of energy estimation. JPEN J Parenter Enteral Nutr 2022; 46(8):1875–82. doi: <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.1002/jpen.2393">10.1002/jpen.2393</ext-link></mixed-citation>
      </ref>
      <ref id="B32">
        <mixed-citation xlink:type="simple">32. Lindner M, Geisler C, Rembarz K, et al. Resting energy expenditure in the critically ill and healthy elderly - a retrospective matched cohort study. Nutrients 2023; 15(2):303. doi: <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.3390/nu15020303">10.3390/nu15020303</ext-link></mixed-citation>
      </ref>
      <ref id="B33">
        <mixed-citation xlink:type="simple">33. Briassoulis P, Ilia S, Briassoulis E, et al. External validation with accuracy confounders of VCO<sub>2</sub>-derived predicted energy expenditure compared to resting energy expenditure measured by indirect calorimetry in mechanically ventilated children. Nutrients 2022; 14(19):4211. doi: <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.3390/nu14194211">10.3390/nu14194211</ext-link></mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>