<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//TaxonX//DTD Taxonomic Treatment Publishing DTD v0 20100105//EN" "../../nlm/tax-treatment-NS0.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:tp="http://www.plazi.org/taxpub" article-type="research-article" dtd-version="3.0" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">87</journal-id>
      <journal-id journal-id-type="index">urn:lsid:arphahub.com:pub:A116C711-4C18-5A38-8F1E-5E97753A8A64</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Folia Medica</journal-title>
        <abbrev-journal-title xml:lang="en">FM</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0204-8043</issn>
      <issn pub-type="epub">1314-2143</issn>
      <publisher>
        <publisher-name>Plovdiv Medical University</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3897/folmed.66.e128267</article-id>
      <article-id pub-id-type="publisher-id">128267</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Review</subject>
        </subj-group>
        <subj-group subj-group-type="scientific_subject">
          <subject>Diagnostic medicine</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>A review of alternative measurements in strain imaging for ventricular arrhythmia prediction</article-title>
      </title-group>
      <contrib-group content-type="authors">
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Kitov</surname>
            <given-names>Spas</given-names>
          </name>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Vladimirova-Kitova</surname>
            <given-names>Lyudmila</given-names>
          </name>
          <email xlink:type="simple">kitov@vip.bg</email>
          <uri content-type="orcid">https://orcid.org/0009-0005-2229-3427</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
      </contrib-group>
      <aff id="A1">
        <label>1</label>
        <addr-line content-type="verbatim">Clinic of Cardiology, Faculty of Medicine, St George University Hospital, Medical University of Plovdiv, Plovdiv, Bulgaria</addr-line>
        <institution>Medical University of Plovdiv</institution>
        <addr-line content-type="city">Plovdiv</addr-line>
        <country>Bulgaria</country>
      </aff>
      <author-notes>
        <fn fn-type="corresp">
          <p>Corresponding author: Lyudmila Vladimirova-Kitova, Clinic of Cardiology, Faculty of Medicine, St George University Hospital, Medical University of Plovdiv, 15A Vassil Aprilov Blvd., 4002 Plovdiv, Bulgaria; Email: <email xlink:type="simple">kitov@vip.bg</email></p>
        </fn>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2024</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>31</day>
        <month>10</month>
        <year>2024</year>
      </pub-date>
      <volume>66</volume>
      <issue>5</issue>
      <fpage>599</fpage>
      <lpage>607</lpage>
      <uri content-type="arpha" xlink:href="http://openbiodiv.net/4F5EDF26-E283-5CC2-818C-531339AE7823">4F5EDF26-E283-5CC2-818C-531339AE7823</uri>
      <history>
        <date date-type="received">
          <day>24</day>
          <month>05</month>
          <year>2024</year>
        </date>
        <date date-type="accepted">
          <day>12</day>
          <month>09</month>
          <year>2024</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>Spas Kitov, Lyudmila Vladimirova-Kitova</copyright-statement>
        <license license-type="creative-commons-attribution" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <abstract>
        <label>Abstract</label>
        <p>Global longitudinal strain has been established as a reliable tool to assess global left ventricular function and a marker of subclinical left ventricular dysfunction unrecognized by the ejection fraction. On the other hand, ventricular arrhythmias are the most common cause of sudden cardiac death. Their early detection is a challenge. Possible prognostic markers for the risk of ventricular arrhythmias are discussed in the literature – electrocardiographic, cardiac magnetic resonance, computed tomography, radionuclide imaging, and markers from new echocardiographic techniques. Of the latter, at this stage of knowledge, several markers have been discussed as informative for predicting ventricular arrhythmias – global longitudinal strain, radial strain and mechanical dispersion, and most recently, myocardial work. As far as we are informed, global longitudinal strain is particularly useful in patients with normal echocardiographic parameters such as left ventricular ejection fraction, left atrial diameter, left ventricular wall thickness, and aortic root. The relationship between mechanical dispersion and ventricular arrhythmias has been widely studied. The relationship has been studied more in some patient populations – heart failure, ischemic heart disease, long QT syndrome and arrhythmogenic cardiomyopathy, congenital heart disease. The role of mechanical dispersion as a predictor of ventricular arrhythmias in metabolic syndrome is scarce.</p>
      </abstract>
      <kwd-group>
        <label>Keywords</label>
        <kwd>ejection fraction</kwd>
        <kwd>global longitudinal strain</kwd>
        <kwd>mechanical dispersion</kwd>
        <kwd>myocardial work</kwd>
        <kwd>radial strain</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement>Project Medical University № ДП ДП 09.2023</funding-statement>
      </funding-group>
    </article-meta>
    <notes>
      <sec sec-type="Citation" id="SECID0EHD">
        <title>Citation</title>
        <p>Vladimirova-Kitova L, Kitov S. A review of alternative measurements in strain imaging for ventricular arrhythmia prediction. Folia Med (Plovdiv) 2024;66(5):599-607. doi: <ext-link xlink:type="simple" ext-link-type="doi" xlink:href="10.3897/folmed.66.e128267">10.3897/folmed.66.e128267</ext-link>.</p>
      </sec>
    </notes>
  </front>
  <body>
    <sec sec-type="Introduction" id="SECID0ETD">
      <title>Introduction</title>
      <p>Cardiac arrests in the emergency rooms are usually caused by disturbances in the heart rhythm such as ventricular fibrillation or ventricular tachycardia. The underlying mechanisms are multifactorial in nature. Heterogenous ventricular activation is most often due to cardiac fibrosis, an aftermath of tissue damage.</p>
      <p>Echocardiography plays an important role in the evaluation of the structural substrate for arrhythmogenesis. The benefits are that it is noninvasive, easily accessible, and portable. Most often this is done by measuring the left ventricular ejection fraction (<abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0E1D">LVEF</abbrev>). For more than 60 years, <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0E5D">LVEF</abbrev> has been a primary tool for assessing systolic function. Its limitations associated with volume-only assessment have been documented over time due to technical constraints, such as poor repeatability, geometric variation, and load dependence.<sup>[<xref ref-type="bibr" rid="B1">1</xref>]</sup> Therefore, ejection fraction is an indirect measure of systolic function. Data in the literature shows that left ventricular ejection fraction is not reliable. This is confirmed by the fact that a majority of patients preserve <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0EJE">LVEF</abbrev> in 30% to 40% of cases of sudden cardiac death in patients with heart failure. Clinical practice needs to have a more reliable parameter than <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0ENE">LVEF</abbrev> to stratify the risk of ventricular arrhythmias.</p>
      <p>Speckle-tracking echocardiography has several advantages for assessing myocardial function. It enables a thorough assessment of cardiac mechanics since strain measurement is extremely sensitive in detecting systolic dysfunction that the ejection fraction cannot detect.<sup>[<xref ref-type="bibr" rid="B2 B3 B4">2–4</xref>]</sup> Global longitudinal strain (<abbrev xlink:title="Global longitudinal strain" id="ABBRID0E1E">GLS</abbrev>) has been established as a reliable tool for assessing global LV function and a marker of subclinical LV dysfunction over the past 15 years.<sup>[<xref ref-type="bibr" rid="B5">5</xref>]</sup></p>
      <p>On the other hand, early identification of patients at risk for ventricular arrhythmias is difficult in clinical practice, particularly in patients with <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0EGF">LVEF</abbrev> &gt;35%, despite the fact that ventricular arrhythmias are the most common cause of sudden cardiac death.<sup>[<xref ref-type="bibr" rid="B6 B7 B8 B9 B10">6–10</xref>]</sup> Possible prognostic markers for ventricular arrhythmia risk are discussed in the literature –electrocardiographic, cardiac magnetic resonance markers, computed tomography, radionuclide imaging and markers from new echocardiographic techniques.<sup>[<xref ref-type="bibr" rid="B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20">8–20</xref>]</sup> Several of these markers are discussed as informative for predicting ventricular arrhythmias –global longitudinal strain, radial strain and mechanical dispersion as potential markers for ventricular arrhythmias, and most recently, myocardial work as a potential marker for arrhythmia risk.<sup>[<xref ref-type="bibr" rid="B21">21</xref>]</sup></p>
      <p>On the one hand, ventricular arrhythmias might develop as a result of channelopathies, toxicity, or other unknown reasons. On the other hand, in practice, structural heart disease is a quite common cause of ventricular arrhythmias. Echocardiography is applied in the evaluation of structural and functional cardiac problems and, in recent years, to detect patients at high risk of ventricular arrhythmia. Mechanical contraction of the heart is an end product of electrical conduction in the heart and cardiomyocyte depolarization (excitation-contraction coupling).‌<sup>[<xref ref-type="bibr" rid="B8">8</xref>]</sup> Pathological changes in myocardial activity magnitude and timing lead to changes in electrocardiogram recordings. These slight electrical variations must logically be transferred into mechanical variations. Intraventricular conduction delay and dispersion (<abbrev xlink:title=" Intraventricular conduction delay and dispersion" id="ABBRID0EHG">QRS</abbrev>) are associated with an increased arrhythmia risk in a number of heart diseases and are commonly assessed by <abbrev xlink:title="Intraventricular conduction delay and dispersion" id="ABBRID0ELG">QRS</abbrev> and QT duration.<sup>[<xref ref-type="bibr" rid="B9">9</xref>]</sup> Physiological variability in <abbrev xlink:title="Intraventricular conduction delay and dispersion" id="ABBRID0EWG">QRS</abbrev> and QTc intervals is associated with slight but significant changes in myocardial deformation patterns. Better longitudinal stress parameters and increased mechanical dyssynchrony have been associated with longer QTc and increased <abbrev xlink:title="Intraventricular conduction delay and dispersion" id="ABBRID0E1G">QRS</abbrev> delay. Integrating the effects of ventricular conduction delay on repolarization, myocardial mechanics, and synchrony is probably going to improve our understanding of electromechanical coupling.<sup>[<xref ref-type="bibr" rid="B9">9</xref>]</sup> The idea of using additional echocardiographic markers for arrhythmogenic burden with electrocardiographic ones has a beneficial practical application. The need of new echocardiographic markers to assess myocardial function and arrhythmogenic burden, and their prognostic value, is the subject of our current review.</p>
      <sec sec-type="Left ventricular echocardiographic parameters for evaluating myocardial function and arrhythmogenic burden and their prognostic value" id="SECID0EFH">
        <title>
          <italic>Left ventricular echocardiographic parameters for evaluating myocardial function and arrhythmogenic burden and their prognostic value</italic>
        </title>
        <sec sec-type="Strain imaging" id="SECID0EMH">
          <title>
            <italic>Strain imaging</italic>
          </title>
          <p>Initially, strain imaging was used as a function of tissue Doppler imaging.<sup>[<xref ref-type="bibr" rid="B22">22</xref>]</sup> From three projections: three-cavity, four-cavity and two-cavity, longitudinal, circumferential, and radial deformations, as well as torsion, are quantified.‌<sup>[<xref ref-type="bibr" rid="B23">23</xref>]</sup> Of the three, longitudinal deformation is the most applicable due to high reproducibility<sup>[<xref ref-type="bibr" rid="B1">1</xref>,<xref ref-type="bibr" rid="B5">5</xref>]</sup>, but also the subendocardial layers where the longitudinal fibers are located are most vulnerable to ischemia<sup>[<xref ref-type="bibr" rid="B23">23</xref>]</sup>. Longitudinal strain provides the best information on cardiac mechanics, by quantifying <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EWAAC">GLS</abbrev>, regional strain, mechanical dispersion (<abbrev xlink:title="mechanical dispersion" id="ABBRID0E1AAC">MD</abbrev>) and, lately, myocardial work as cardiovascular outcome potential markers, including arrhythmia risk.</p>
        </sec>
        <sec sec-type="Global longitudinal strain of the left ventricle" id="SECID0E5AAC">
          <title>
            <italic>Global longitudinal strain of the left ventricle</italic>
          </title>
          <p>Data in the literature in recent years demonstrate that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EHBAC">GLS</abbrev> can detect left ventricular systolic dysfunction at an earlier stage than the ejection fraction.<sup>[<xref ref-type="bibr" rid="B24">24</xref>]</sup> This fact has its own logical explanation. Ejection fraction is based on volume measurements, while <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ESBAC">GLS</abbrev> assesses myocardial contractile function. Therefore, the first is an indirect surrogate, and the second a direct surrogate of systolic function. Secondly, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EWBAC">GLS</abbrev> reflects the function of the longitudinal fibers that are in the subendocardium, and they are the ones that are most vulnerable to ischemia. It is a fact that coronary perfusion spreads from the subendocardium to the subepicardium. And, last but not least, there is much data that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E1BAC">GLS</abbrev> correlates with the size of the infarct area, with myocardial fibrosis and the neurohumoral response.<sup>[<xref ref-type="bibr" rid="B25">25</xref>,<xref ref-type="bibr" rid="B26">26</xref>]</sup></p>
          <p><bold>Fig. <xref ref-type="fig" rid="F1">1</xref></bold> shows <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EQCAC">GLS</abbrev> (18% –slightly decreased) in a patient with normal <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0EUCAC">LVEF</abbrev> (62%) and normal <abbrev xlink:title="mechanical dispersion" id="ABBRID0EYCAC">MD</abbrev> (44.8 msec). These results suggest more frequent monitoring of these parameters. A decrease in <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E3CAC">GLS</abbrev> and a prolongation of <abbrev xlink:title="mechanical dispersion" id="ABBRID0EADAC">MD</abbrev> will lead to a change in therapeutic behavior.</p>
          <fig id="F1" position="float" orientation="portrait">
            <object-id content-type="arpha">4A95A780-4DFC-5AD5-B824-BE636F404D85</object-id>
            <label>Figure 1.</label>
            <caption>
              <p>Examples of the longitudinal strain bull’s eye plot in a patient with arterial hypertension, a 55-year-old male; metabolic syndrome; basal septal wall thickness is 14 mm, left ventricular posterior wall end diastole is 9 mm, and <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0EMDAC">LVEF</abbrev> is 62%.</p>
            </caption>
            <graphic xlink:href="foliamedica-66-5-e128267-g001.jpg" position="float" orientation="portrait" xlink:type="simple" id="oo_1168834.jpg">
              <uri content-type="original_file">https://binary.pensoft.net/fig/1168834</uri>
            </graphic>
          </fig>
          <p>At this stage of knowledge, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EXDAC">GLS</abbrev> is particularly suitable for patients with normal echocardiographic parameters such as left ventricular ejection fraction, left atrial diameter, left ventricular wall thickness, and aortic root.</p>
        </sec>
        <sec sec-type="Informative value of GLS for ventricular arrhythmias" id="SECID0E2DAC">
          <title>
            <italic>Informative value of <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ECEAC">GLS</abbrev> for ventricular arrhythmias</italic>
          </title>
          <p>Data from the literature demonstrate that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EJEAC">GLS</abbrev> is prognostic in relation to cardiovascular events, in contrast to ejection fraction and Killip class.<sup>[<xref ref-type="bibr" rid="B27 B28 B29">27–29</xref>]</sup> Despite heterogeneity in endpoints, monitoring and duration of follow-up, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EUEAC">GLS</abbrev> predicts ventricular arrhythmias. Moreover, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EYEAC">GLS</abbrev> can be used to select candidates suitable for an implantable cardioverter defibrillator (<abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0E3EAC">ICD</abbrev>).</p>
          <p>At this stage, ventricular arrhythmia and sudden cardiac death risk stratification at an ejection fraction below 35% is considered suboptimal. But at present, it is relied mainly on this fact.<sup>[<xref ref-type="bibr" rid="B30 B31 B32">30–32</xref>]</sup> In a study by Ersbøll et al., the authors established the significance of <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EJFAC">GLS</abbrev> provides important prognostic information in patients with LVEFs &gt;40% above and beyond traditional indexes of high-risk MI.<sup>[<xref ref-type="bibr" rid="B11">11</xref>]</sup></p>
          <p>In a prospective study, Ersbøll et al. state that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EVFAC">GLS</abbrev> leads to the determination of the risk of ventricular arrhythmias in myocardial infarction acute phase of up to 48 hours. Both <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EZFAC">GLS</abbrev> and <abbrev xlink:title="mechanical dispersion" id="ABBRID0E4FAC">MD</abbrev> were significantly and independently related to sudden cardiac death/ventricular arrhythmias in these patients with acute myocardial infarction. In this study <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EBGAC">GLS</abbrev> improved risk stratification above and beyond existing risk factors. <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EFGAC">GLS</abbrev> was significantly reduced in patients who presented with ventricular arrhythmias compared to patients who did not.<sup>[<xref ref-type="bibr" rid="B13">13</xref>]</sup></p>
          <p>According to data from Haugaa et al., in patients with a prolonged QT interval it was observed that left ventricular mechanical dispersion measured by tissue Doppler imaging was superior to the corrected QT interval.<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup> This could better the clinical approach in patients with a prolonged QT interval.</p>
          <p>A study by the same team Haugaa et al. in patients after myocardial infarction and <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0E1GAC">ICD</abbrev>, only the combination of <abbrev xlink:title="mechanical dispersion" id="ABBRID0E5GAC">MD</abbrev> and <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ECHAC">GLS</abbrev> can select with greater precision suitable patients for <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0EGHAC">ICD</abbrev> therapy, especially those with an ejection fraction of &gt;35%. The study has multiple limitations of a technical nature.<sup>[<xref ref-type="bibr" rid="B34">34</xref>]</sup></p>
          <p>In patients with a corrected tetralogy of Fallot, Van Grootel et al. discovered that left ventricular as well as right ventricular longitudinal strain add additional information to the routine prognostic risk evaluation of sudden cardiac death and the development of heart failure.<sup>[<xref ref-type="bibr" rid="B35">35</xref>]</sup></p>
          <p>In ischemic heart disease, the role of <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E1HAC">GLS</abbrev> as a ventricular arrhythmia prognostic marker is controversial. A meta-analysis found that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E5HAC">GLS</abbrev> was not associated with ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B16">16</xref>]</sup></p>
          <p>Data from a large study such as MADIT-CRT provides strong evidence unlike meta-analyses. In myocardial infarction, there is other data that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EKIAC">GLS</abbrev> predicts ventricular arrhythmias, but in a retrospective analysis or in a composite outcome with heart failure or mortality. In a substudy of MADIT-CRT with continuous rhythm monitoring and assessment of ventricular arrhythmias<sup>[<xref ref-type="bibr" rid="B36">36</xref>]</sup>, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EVIAC">GLS</abbrev> was found to correlate with ventricular arrhythmias in nonischemic cardiomyopathies. Regardless of the small number of patients with nonischemic cardiomyopathy, greater <abbrev xlink:title="mechanical dispersion" id="ABBRID0EZIAC">MD</abbrev> was associated with a higher incidence of ventricular tachycardia (<abbrev xlink:title="incidence of ventricular tachycardia" id="ABBRID0E4IAC">VT</abbrev>), ventricular fibrillation (<abbrev xlink:title="ventricular fibrillation" id="ABBRID0EBJAC">VF</abbrev>).<sup>[<xref ref-type="bibr" rid="B37">37</xref>]</sup></p>
          <p>Data from the beginning of 2024 shows that <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ENJAC">GLS</abbrev> is a useful indicator in finding suitable patients with hypertrophic cardiomyopathy who are implantable cardioverter defibrillator candidates, confirming the strong link between <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ERJAC">GLS</abbrev> and fatal arrhythmias and sudden cardiac death.<sup>[<xref ref-type="bibr" rid="B38">38</xref>]</sup></p>
        </sec>
      </sec>
      <sec sec-type="Mechanical dyssynchrony, mechanical dispersion and ventricular arrhythmia" id="SECID0E2JAC">
        <title>
          <italic>Mechanical dyssynchrony, mechanical dispersion and ventricular arrhythmia</italic>
        </title>
        <sec sec-type="Nature of mechanical dyssynchrony" id="SECID0ECKAC">
          <title>
            <italic>Nature of mechanical dyssynchrony</italic>
          </title>
          <p>Mechanical dyssynchrony represents the inhomogeneity of myocardial contraction within the boundaries of the left ventricle. For several decades, mechanical dyssynchrony has been applied in ventricular arrhythmia prediction in specific patient groups and to identify those suitable for resynchronization therapy. In medical practice, mechanical dispersion is the most commonly used measure of dyssynchrony.<sup>[<xref ref-type="bibr" rid="B39">39</xref>]</sup></p>
        </sec>
        <sec sec-type="Nature of ﻿mechanical dispersion" id="SECID0ERKAC">
          <title>
            <italic>Nature of ﻿mechanical dispersion</italic>
          </title>
          <p>Generally, in a 16-segment model, <abbrev xlink:title="mechanical dispersion" id="ABBRID0E1KAC">MD</abbrev> is defined as the standard deviation of peak longitudinal strain time. <abbrev xlink:title="mechanical dispersion" id="ABBRID0E5KAC">MD</abbrev> has excellent reproducibility (intra–and interobserver –0.95 and 0.94).<sup>[<xref ref-type="bibr" rid="B40">40</xref>]</sup> Fibrosis results in a heterogeneous contraction pattern as it leads to electrical dispersion. The latter affects the activation time as well as the refractoriness. <abbrev xlink:title="mechanical dispersion" id="ABBRID0EJLAC">MD</abbrev> correlates with fibrosis, therefore correlates with the risk of ventricular arrhythmias. Data on <abbrev xlink:title="mechanical dispersion" id="ABBRID0ENLAC">MD</abbrev> in healthy subjects are scarce, and it has mainly been studied to predict ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B41">41</xref>]</sup></p>
          <p>﻿Rodríguez-Zenella et al. are the only ones that set themselves the task of determining reference values in healthy people. They studied 334 healthy volunteers (Caucasian race, mean age 54 years, 54% female). They found a total normal value of 34±10 ms with an upper limit of 56 ms. No difference in <abbrev xlink:title="mechanical dispersion" id="ABBRID0EZLAC">MD</abbrev> was found between men and women, but it increased with age. The authors found that age, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E4LAC">GLS</abbrev>, and E/e’ were independently correlated to <abbrev xlink:title="mechanical dispersion" id="ABBRID0EBMAC">MD</abbrev>.<sup>[<xref ref-type="bibr" rid="B40">40</xref>]</sup></p>
          <p>Aagaard et al. studied not only healthy individuals but included 2529 participants. They found that ischemic heart disease, hypertension, <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ENMAC">GLS</abbrev>, e’ and left ventricular ejection fraction correlated with higher <abbrev xlink:title="mechanical dispersion" id="ABBRID0ERMAC">MD</abbrev>.<sup>[<xref ref-type="bibr" rid="B28">28</xref>]</sup></p>
        </sec>
        <sec sec-type="Mechanical dispersion and ventricular arrhythmias" id="SECID0E2MAC">
          <title>
            <italic>Mechanical dispersion and ventricular arrhythmias</italic>
          </title>
          <p>The association between <abbrev xlink:title="mechanical dispersion" id="ABBRID0EENAC">MD</abbrev> and ventricular arrhythmias has been widely studied, similarly to <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EINAC">GLS</abbrev>. Some patient populations have been studied more thoroughly – those with heart failure<sup>[<xref ref-type="bibr" rid="B29">29</xref>,<xref ref-type="bibr" rid="B42">42</xref>]</sup> and ischemic heart disease<sup>[<xref ref-type="bibr" rid="B14">14</xref>,<xref ref-type="bibr" rid="B32">32</xref>]</sup>, prolonged QT interval syndrome<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup> and arrhythmogenic cardiomyopathy<sup>[<xref ref-type="bibr" rid="B34">34</xref>]</sup>, also in congenital heart disease<sup>[<xref ref-type="bibr" rid="B35">35</xref>]</sup>. There are two systematic reviews evaluating the potential of <abbrev xlink:title="mechanical dispersion" id="ABBRID0EXOAC">MD</abbrev> to predict ventricular arrhythmias.</p>
          <p>Kawakami et al. made an ischemic cardiomyopathy meta-analysis, including 12 studies with a total of 3198 patients during 17 to 70 months of follow-up. The analysis showed higher <abbrev xlink:title="mechanical dispersion" id="ABBRID0E4OAC">MD</abbrev> in patients with ventricular arrhythmias and independently associated with them, and that <abbrev xlink:title="mechanical dispersion" id="ABBRID0EBPAC">MD</abbrev> was better than left ventricular ejection fraction and <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EFPAC">GLS</abbrev> for prediction of ventricular arrhythmias. A limiting factor is the heterogeneity of the included studies. However, Kawakami et al. discovered that a 1-SD change in LVMD was a stronger predictor of VA events compared with the same changes in <abbrev xlink:title="left ventricular ejection fraction" id="ABBRID0EJPAC">LVEF</abbrev> and <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ENPAC">GLS</abbrev>. The patients with VA events had significantly greater mechanical dispersion compared with those without VA events, with 60 ms being an acceptable cutoff LVMD value for predicting VA events. An interesting claim made by Kawakami et al. is that <abbrev xlink:title="mechanical dispersion" id="ABBRID0ERPAC">MD</abbrev> in CRT patients cannot predict ventricular arrhythmias because CRT influences arrhythmia risk and regional timing.<sup>[<xref ref-type="bibr" rid="B16">16</xref>]</sup></p>
          <p>Unlike previous data, Harapoz et al. presented the possibilities of <abbrev xlink:title="mechanical dispersion" id="ABBRID0E4PAC">MD</abbrev> in 346 patients with non-ischemic cardiomyopathy in a meta-analysis, finding no significant association between <abbrev xlink:title="mechanical dispersion" id="ABBRID0ECAAE">MD</abbrev> and ventricular arrhythmias. A limiting factor is the small number of subjects included. What remains an open question is whether <abbrev xlink:title="mechanical dispersion" id="ABBRID0EGAAE">MD</abbrev> is an important ventricular arrhythmia predictor in non-ischemic cardiomyopathy as opposed to ischemic cardiomyopathy, in which pathophysiological mechanisms lead to the spread of fibrosis in the myocardium.<sup>[<xref ref-type="bibr" rid="B42">42</xref>]</sup></p>
          <p>In the MADIT-CRT study of 1064 patients with continuous rhythm monitoring, Biering-Sørensen et al. found that for a mean of 2.9 years, those who had ventricular arrhythmias had similar <abbrev xlink:title="mechanical dispersion" id="ABBRID0ESAAE">MD</abbrev> to those without ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B36">36</xref>]</sup></p>
          <p>Kutyifa et al. claim in their analysis that baseline <abbrev xlink:title="mechanical dispersion" id="ABBRID0E5AAE">MD</abbrev> does not predict ventricular arrhythmias. However, patients with left-bundle branch block CRT who improved their <abbrev xlink:title="mechanical dispersion" id="ABBRID0ECBAE">MD</abbrev> after 12 months had a lower risk of ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B39">39</xref>]</sup> Van der Bijl et al. drew similar conclusions in a retrospective study of 1185 patients, namely that <abbrev xlink:title="mechanical dispersion" id="ABBRID0ENBAE">MD</abbrev> at 6 months predicted ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B32">32</xref>]</sup> Almost all relevant studies highlight the important issue that the timing of <abbrev xlink:title="mechanical dispersion" id="ABBRID0EYBAE">MD</abbrev> examination is very important when evaluating its prognostic value.</p>
          <p>In the MeDiPace transcatheter aortic valve implantation study, <abbrev xlink:title="mechanical dispersion" id="ABBRID0E5BAE">MD</abbrev> was considerably higher in patients who required a pacemaker following transcatheter aortic valve implantation compared with patients without a pacemaker. Additionally, <abbrev xlink:title="mechanical dispersion" id="ABBRID0ECCAE">MD</abbrev> and right-bundle branch block were independent predictors of pacemaker implantation following transcatheter aortic valve implantation. <abbrev xlink:title="mechanical dispersion" id="ABBRID0EGCAE">MD</abbrev> improves prognosis when combined with right-bundle branch block. These results suggest that PM implantation in patients with normal <abbrev xlink:title="mechanical dispersion" id="ABBRID0EKCAE">MD</abbrev> should be avoided.<sup>[<xref ref-type="bibr" rid="B43">43</xref>]</sup></p>
          <p>In a 2020 study in the middle-aged general population, the predominant coronary heart disease and hypertension were linked to increased mechanical variance, which probably indicates an increased fatal arrhythmia and sudden cardiac death risk. Although less severe, systolic and diastolic dysfunction are also linked to increased mechanical dispersion.<sup>[<xref ref-type="bibr" rid="B28">28</xref>]</sup></p>
          <p>There is scarce data in the literature on <abbrev xlink:title="mechanical dispersion" id="ABBRID0E5CAE">MD</abbrev> in patients with metabolic syndrome, which covers a huge cohort of patients in clinical practice, with the scope of a pandemic.‌<sup>[<xref ref-type="bibr" rid="B44">44</xref>]</sup> The term “metabolic syndrome” encompasses a group of disorders characterized by central obesity, hypertension, impaired glucose tolerance, and atherogenic dyslipidemia. Insulin resistance and type 2 diabetes cause a variety of functional, metabolic and structural changes leading to myocardial damage and heart failure progression. Echocardiography is a first-line research method for studying cardiac structural and functional changes associated with metabolic syndrome and type 2 diabetes. As the review of literature shows, changes in all indicators of left and right ventricular systolic and diastolic function in metabolic syndrome have not been studied. 2D strain echocardiography can detect early left ventricular dysfunction as well as the asymptomatic stage of metabolic syndrome. The latter affects the functional state of the heart by causing a decrease in <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EJDAE">GLS</abbrev>. In the case of normal <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ENDAE">GLS</abbrev> in metabolic syndrome, regional strain is reduced. <abbrev xlink:title="Global longitudinal strain" id="ABBRID0ERDAE">GLS</abbrev> reference limits in metabolic syndrome patients have not been established. Data on the role of <abbrev xlink:title="mechanical dispersion" id="ABBRID0EVDAE">MD</abbrev> as a ventricular arrhythmia predictor in metabolic syndrome is scarce.<sup>[<xref ref-type="bibr" rid="B45">45</xref>]</sup></p>
        </sec>
        <sec sec-type="Regional strain ﻿of the left ventricle" id="SECID0E6DAE">
          <title>
            <italic>Regional strain ﻿of the left ventricle</italic>
          </title>
          <p><abbrev xlink:title="Global longitudinal strain" id="ABBRID0EIEAE">GLS</abbrev> demonstrates the global LV deformation, the assessment of the tissue deformation in certain areas of the left ventricle is done by regional strain. Through the gold standard examination of the myocardium, it is established that longitudinal and radial deformation are progressively impaired by non-, peri- and infarct zones.<sup>[<xref ref-type="bibr" rid="B32">32</xref>]</sup></p>
          <p>In the VALIANT study, regional strain was found to be impaired in areas that were assessed as normokinetic. On the other hand, a greater number of segments with impaired regional strain is associated with higher mortality and heart failure.<sup>[<xref ref-type="bibr" rid="B46">46</xref>]</sup></p>
          <p>Biering-Sørensen et al. reveal a very important clinical fact that reduced regional strain outside the area of the culprit artery demonstrates limited reserve after myocardial infarction.<sup>[<xref ref-type="bibr" rid="B20">20</xref>]</sup> There is evidence that regional strain is associated with a greater likelihood of left ventricular thrombus formation. A limiting factor for regional strain compared to <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EDFAE">GLS</abbrev> is its poorer reproducibility and heterogeneity.<sup>[<xref ref-type="bibr" rid="B7">7</xref>]</sup></p>
        </sec>
        <sec sec-type="Informative value of regional strain for ventricular arrhythmias" id="SECID0ENFAE">
          <title>
            <italic>Informative value of regional strain for ventricular arrhythmias</italic>
          </title>
          <p>In myocardial infarction patients, the presence of fibrous tissue in the myocardial zone is the substrate with arrhythmogenic potential. At the same time, the peri-infarct zone has intermediate non-transmural fibrosis, which leads to electrical dispersion, delayed conduction, and one-way block. The latter produce substrates for ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B47">47</xref>]</sup></p>
          <p>There is scarce data in the literature on the informative value of regional strain in relation to ventricular arrhythmias than <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E5FAE">GLS</abbrev> and <abbrev xlink:title="mechanical dispersion" id="ABBRID0ECGAE">MD</abbrev>. Nguyen et al. studied the potential of regional strain to predict <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0EGGAE">ICD</abbrev> in 424 ischemic cardiomyopathy and a prophylactic implanted cardioverter defibrillator patients. It was found that regional strain in the peri-infarct zone was independently related to the need for an <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0EKGAE">ICD</abbrev>.<sup>[<xref ref-type="bibr" rid="B17">17</xref>]</sup> Hoogslag et al. studied the informativeness of regional strain for predicting proper treatment with <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0EVGAE">ICD</abbrev> or cardiac mortality by echocardiography at baseline and at 3 months in 79 patients with myocardial infarction. No difference was found in regional strain identified in infarct, peri-infarct or remote area at baseline between patients.<sup>[<xref ref-type="bibr" rid="B48">48</xref>]</sup></p>
          <p>In a 25-month follow-up of 51 patients with documented ventricular arrhythmias or 24-hour Holter monitoring, recording at hospitalization or electrophysiological examination. Data shows that longitudinal and circumferential strain demonstrate high AUCs for detecting ventricular arrhythmias. Furthermore, only abnormal circumferential peri-infarct strain and <abbrev xlink:title="mechanical dispersion" id="ABBRID0EBHAE">MD</abbrev> were independently related to ventricular arrhythmias. More massive myocardial infarctions are not limited to subendocardial ischemia, reflected in <abbrev xlink:title="Global longitudinal strain" id="ABBRID0EFHAE">GLS</abbrev>, but also reduce circumferential strain.<sup>[<xref ref-type="bibr" rid="B37">37</xref>]</sup></p>
          <p>In heart failure patients, MADIT-CRT is the largest study to investigate the potential of regional longitudinal strain and its role in predicting ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B36">36</xref>]</sup></p>
          <p>Biering-Sørensen et al. studied 1064 patients and found that longitudinal strain in the lower and posterior segments of the left ventricular wall correlated with the occurrence of ventricular tachycardia/flutter.<sup>[<xref ref-type="bibr" rid="B20">20</xref>]</sup> A study from Denmark with 401 patients demonstrated the association between inferior wall deformation and ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B24">24</xref>]</sup> One of the hangings is differentiation of the parasympathetic and sympathetic innervation of the left ventricle and differential deformation of the wall.<sup>[<xref ref-type="bibr" rid="B25">25</xref>]</sup></p>
          <p>Data from the literature verify the gold standard of cardiac MRI to anatomically detect areas of dysfunctional myocardium and predict ventricular arrhythmias and mortality.<sup>[<xref ref-type="bibr" rid="B49">49</xref>]</sup></p>
        </sec>
        <sec sec-type="Guidelines for future research on strain measurements" id="SECID0EVIAE">
          <title>
            <italic>Guidelines for future research on strain measurements</italic>
          </title>
          <p>Although <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E5IAE">GLS</abbrev>, <abbrev xlink:title="mechanical dispersion" id="ABBRID0ECJAE">MD</abbrev>, and regional strain are the most widely studied strain indicators in terms of predicting ventricular arrhythmias, theoretically any other indicators of myocardial mechanics may have prognostic value. The latter include indicators of paradoxical movement and myocardial work. However, currently, their associations with ventricular arrhythmias have been poorly studied.</p>
          <p>Paradoxical motion is a change in myocardial tissue motion, with left ventricular segments lengthening when they should be shortening. In clinical practice, it most often appears as early systolic lengthening or as postsystolic shortening. Paradoxical motion is most commonly observed in ischemic heart disease and shows ischemic segments with potential tissue viability. Nevertheless, they can also occur in other conditions, including conduction abnormalities and mitral annular disjunction. It should also be mentioned that to some extent, they may occur under regular circumstances as part of normal physiology. These indices of myocardial deformation are highly correlated with ischemia and possibly with the extent of myocardial involvement. It is logical that they are also markers for an increased risk of ventricular arrhythmias. But this claim needs to be proven.<sup>[<xref ref-type="bibr" rid="B50">50</xref>]</sup></p>
          <p>In a study of 569 patients, Haugaa et al. found that patients who developed ventricular arrhythmias had a higher degree of postsystolic shortening, (postsystolic stress index), compared to patients without ventricular arrhythmias. All patients had a left ventricular ejection fraction &gt;35%. Postsystolic strain index was not an independent predictor of ventricular arrhythmias when <abbrev xlink:title="mechanical dispersion" id="ABBRID0EQJAE">MD</abbrev> was included.<sup>[<xref ref-type="bibr" rid="B33">33</xref>]</sup> Groeneveld et al. also demonstrated a more frequent and widespread postsystolic shortening in patients with idiopathic ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B51">51</xref>]</sup></p>
          <p>The latest trend in strain development is a new method for assessing myocardial performance with pressure-strain loop analysis. This method, introduced by Russell et al. in 2012, enables assessment of the myocardial performance by combining data on strain, arterial blood pressure, and valvular event time. This method has excellent reproducibility. Inclusion of arterial pressure as an afterload assessment assesses systolic function in more detail.<sup>[<xref ref-type="bibr" rid="B52">52</xref>]</sup></p>
          <p>Practical approaches to measure myocardial performance are described in detail in the literature. A significant point in the measurement is the information obtained about the constructive work, wasted work and work efficiency. All three are affected by the paradoxicality of motion. And the latter can point us to the risk of ventricular arrhythmias.<sup>[<xref ref-type="bibr" rid="B53">53</xref>]</sup></p>
          <p>In a meta-analysis, Truong et al. provide echocardiographic reference ranges for noninvasive indices of myocardial work. As reference for clinical and research use these normal values could serve. Echocardiographic reference ranges for indices of myocardial work were established. Gender significantly contributed to variations in normal values of myocardial work. Myocardial work indices had excellent and good intra- and interobserver reproducibility.<sup>[<xref ref-type="bibr" rid="B54">54</xref>]</sup> It is yet to be proven whether or not evaluating myocardial work has a clinical relevance.</p>
          <p>At this stage, it is assumed that myocardial performance provides clinical information superior to <abbrev xlink:title="Global longitudinal strain" id="ABBRID0E3KAE">GLS</abbrev>. This is what the literature shows. A case report by Jaworski et al. discusses the possible application of regional work in a patient with ventricular fibrillation.<sup>[<xref ref-type="bibr" rid="B55">55</xref>]</sup> In a study of hypertrophic cardiomyopathy in 110 patients, Hiemstra et al. found constructive work to be a predictor of a composite clinical endpoint that included sudden cardiac death and <abbrev xlink:title="implantable cardioverter defibrillator" id="ABBRID0EHLAE">ICD</abbrev> therapy, which was found in 11 of 24 cases.<sup>[<xref ref-type="bibr" rid="B56">56</xref>]</sup></p>
          <p>Currently, there is no data on the relationship between myocardial performance and ventricular arrhythmia risk. This question remains to be clarified in additional clinical studies.</p>
        </sec>
      </sec>
    </sec>
    <sec sec-type="Conclusion" id="SECID0ESLAE">
      <title>Conclusion</title>
      <p>Data on the relationship of strain assessment (<abbrev xlink:title="Global longitudinal strain" id="ABBRID0EYLAE">GLS</abbrev> and <abbrev xlink:title="mechanical dispersion" id="ABBRID0E3LAE">MD</abbrev>) and ventricular arrhythmias in a large spectrum of cardiovascular diseases demonstrate likely clinical utility. At this stage, there is a lack of studies that evaluate whether or not a patient is suitable for an implantable cardioverter defibrillator by randomizing based on strain measurement. The new methods –paradoxical movement and myocardial work are far from being a prognostic factor. Much more research is necessary in this direction, but the need for the clinician to support these methodologies is likely to give impetus to such research.</p>
    </sec>
    <sec sec-type="Acknowledgements" id="SECID0EAMAE">
      <title>Acknowledgements</title>
      <p>The authors have no support to report.</p>
    </sec>
    <sec sec-type="Funding" id="SECID0EFMAE">
      <title>Funding</title>
      <p>The authors have no funding to report.</p>
    </sec>
    <sec sec-type="Competing Interests" id="SECID0EKMAE">
      <title>Competing Interests</title>
      <p>The authors have declared that no competing interests exist.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <mixed-citation xlink:type="simple">1. Karlsen S, Dahlslett T, Grenne B, et al. Global longitudinal strain is a more reproducible measure of left ventricular function than ejection fraction regardless of echocardiographic training. Cardiovasc Ultrasound 2019; 17:18.</mixed-citation>
      </ref>
      <ref id="B2">
        <mixed-citation xlink:type="simple">2. Stecker EC, Vickers C, Waltz J, et al. Population-based analysis of sudden cardiac death with and without left ventricular systolic dysfunction: two-year findings from the Oregon Sudden Unexpected Death Study. J Am Coll Cardiol 2006; 47(6):1161–6.</mixed-citation>
      </ref>
      <ref id="B3">
        <mixed-citation xlink:type="simple">3. Goldberger JJ, Subačius H, Patel T, et al. Sudden cardiac death risk stratification in patients with nonischemic dilated cardiomyopathy. J Am Coll Cardiol 2014; 63(18):1879–89.</mixed-citation>
      </ref>
      <ref id="B4">
        <mixed-citation xlink:type="simple">4. Vaduganathan M, Patel RB, Michel A, et al. Mode of death in heart failure with preserved ejection fraction. J Am Coll Cardiol 2017; 69(5):556–69.</mixed-citation>
      </ref>
      <ref id="B5">
        <mixed-citation xlink:type="simple">5. Pfeiffer ER, Tangney JR, Omens JH, et al. Biomechanics of cardiac electromechanical coupling and mechanoelectric feedback. J Biomech Eng 2014; 136(2):021007.</mixed-citation>
      </ref>
      <ref id="B6">
        <mixed-citation xlink:type="simple">6. Verdugo-Marchese M, Coiro S, Selton-Suty C, et al. Left ventricular myocardial deformation pattern, mechanical dispersion, and their relations with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling. Eur Heart J Cardiovasc Imaging 2020; 21(11):1237–45.</mixed-citation>
      </ref>
      <ref id="B7">
        <mixed-citation xlink:type="simple">7. Bjerregaard CL, Skaarup KG, Lassen MCH, et al. Strain imaging and ventricular arrhythmia. Diagnostics (Basel) 2023; 13(10):1778.</mixed-citation>
      </ref>
      <ref id="B8">
        <mixed-citation xlink:type="simple">8. Negishi K, Negishi T, Kurosawa K, et al. Practical guidance in echocardiographic assessment of global longitudinal strain. JACC Cardiovasc Imaging 2015; 8:489–92.</mixed-citation>
      </ref>
      <ref id="B9">
        <mixed-citation xlink:type="simple">9. DeVore AD, McNulty S, Alenezi F, et al. Impaired left ventricular global longitudinal strain in patients with heart failure with preserved ejection fraction: Insights from the RELAX trial. Eur J Heart Fail 2017; 19:893–900.</mixed-citation>
      </ref>
      <ref id="B10">
        <mixed-citation xlink:type="simple">10. Munk K, Andersen NH, Nielsen SS, et al. Global longitudinal strain by speckle tracking for infarct size estimation. Eur J Echocardiogr 2011; 12:156–65.</mixed-citation>
      </ref>
      <ref id="B11">
        <mixed-citation xlink:type="simple">11. Ersbøll M, Valeur N, Mogensen UM, et al. Prediction of all-cause mortality and heart failure admissions from global left ventricular longitudinal strain in patients with acute myocardial infarction and preserved left ventricular ejection fraction. J Am Coll Cardiol 2013; 61:2365–73.</mixed-citation>
      </ref>
      <ref id="B12">
        <mixed-citation xlink:type="simple">12. Santangeli P, Dello Russo A, Casella M, et al. Left ventricular ejection fraction for the risk stratification of sudden cardiac death: Friend or foe? Intern Med J 2011; 41:55–60.</mixed-citation>
      </ref>
      <ref id="B13">
        <mixed-citation xlink:type="simple">13. Ersbøll M, Valeur N, Andersen MJ, et al. Early echocardiographic deformation analysis for the prediction of sudden cardiac death and life-threatening arrhythmias after myocardial infarction. JACC Cardiovasc Imaging 2013; 6:851–60.</mixed-citation>
      </ref>
      <ref id="B14">
        <mixed-citation xlink:type="simple">14. Haugaa KH, Grenne BL, Eek CH, et al. Strain echocardiography improves risk prediction of ventricular arrhythmias after myocardial infarction. JACC Cardiovasc Imaging 2013; 6:841–50.</mixed-citation>
      </ref>
      <ref id="B15">
        <mixed-citation xlink:type="simple">15. Haugaa KH, Smedsrud MK, Steen T, et al. Mechanical dispersion assessed by myocardial strain in patients after myocardial infarction for risk prediction of ventricular arrhythmia. JACC Cardiovasc Imaging 2010; 3:247–56.</mixed-citation>
      </ref>
      <ref id="B16">
        <mixed-citation xlink:type="simple">16. Kawakami H, Nerlekar N, Haugaa KH, et al. Prediction of ventricular arrhythmias with left ventricular mechanical dispersion. JACC Cardiovasc Imaging 2020; 13:562–72.</mixed-citation>
      </ref>
      <ref id="B17">
        <mixed-citation xlink:type="simple">17. Nguyen BL, Capotosto L, Persi A, et al. Global and regional left ventricular strain indices in post-myocardial infarction patients with ventricular arrhythmias and moderately abnormal ejection fraction. Ultrasound Med Biol 2015; 41:407–17.</mixed-citation>
      </ref>
      <ref id="B18">
        <mixed-citation xlink:type="simple">18. Yu S, Zhou J, Yang K, et al. Correlation of myocardial strain and late gadolinium enhancement by cardiac magnetic resonance after a first anterior ST-segment elevation myocardial infarction. Front Cardiovasc Med 2021; 8:705487.</mixed-citation>
      </ref>
      <ref id="B19">
        <mixed-citation xlink:type="simple">19. Wang N, Hung CL, Shin SH, et al. Regional cardiac dysfunction and outcome in patients with left ventricular dysfunction, heart failure, or both after myocardial infarction. Eur Heart J 2016; 37:466–72.</mixed-citation>
      </ref>
      <ref id="B20">
        <mixed-citation xlink:type="simple">20. Biering-Sørensen T, Jensen JS, Pedersen SH, et al. Regional longitudinal myocardial deformation provides incremental prognostic information in patients with ST-segment elevation myocardial infarction. PLoS One 2016; 11:e0158280.</mixed-citation>
      </ref>
      <ref id="B21">
        <mixed-citation xlink:type="simple">21. Amzulescu MS, Langet H, Saloux E, et al. Head-to-head comparison of global and regional two-dimensional speckle tracking strain versus cardiac magnetic resonance tagging in a multicenter validation study. Circ Cardiovasc Imaging 2017; 10:e006530.</mixed-citation>
      </ref>
      <ref id="B22">
        <mixed-citation xlink:type="simple">22. Verma A, Marrouche NF, Schweikert RA, et al. Relationship between successful ablation sites and the scar border zone defined by substrate mapping for ventricular tachycardia post-myocardial infarction. J Cardiovasc Electrophysiol 2005; 16:465–71.</mixed-citation>
      </ref>
      <ref id="B23">
        <mixed-citation xlink:type="simple">23. Hoogslag GE, Thijssen J, Höke U, et al. Prognostic implications of left ventricular regional function heterogeneity assessed with two-dimensional speckle tracking in patients with ST-segment elevation myocardial infarction and depressed left ventricular ejection fraction. Heart Vessel 2014; 29:619–28.</mixed-citation>
      </ref>
      <ref id="B24">
        <mixed-citation xlink:type="simple">24. Winsløw U, Elming M, Thune JJ, et al. Reduced inferior wall longitudinal strain is associated with malignant arrhythmias in non-ischemic heart failure. Pacing Clin Electrophysiol 2023; 46(7):721–8.</mixed-citation>
      </ref>
      <ref id="B25">
        <mixed-citation xlink:type="simple">25. Sasano T, Abraham MR, Chang KC, et al. Abnormal sympathetic innervation of viable myocardium and the substrate of ventricular tachycardia after myocardial infarction. J Am Coll Cardiol 2008; 51:2266–75.</mixed-citation>
      </ref>
      <ref id="B26">
        <mixed-citation xlink:type="simple">26. Tayal B, Gorcsan J, Delgado-Montero A, et al. Mechanical dyssynchrony by tissue Doppler cross-correlation is associated with risk for complex ventricular arrhythmias after cardiac resynchronization therapy. J Am Soc Echocardiogr 2015; 28:1474–81.</mixed-citation>
      </ref>
      <ref id="B27">
        <mixed-citation xlink:type="simple">27. Rodríguez-Zanella H, Haugaa K, Boccalini F, et al. Physiological determinants of left ventricular mechanical dispersion: a 2-dimensional speckle tracking echocardiographic study in healthy volunteers. JACC Cardiovasc Imaging 2018; 11:650–1.</mixed-citation>
      </ref>
      <ref id="B28">
        <mixed-citation xlink:type="simple">28. Aagaard EN, Kvisvik B, Pervez MO, et al. Left ventricular mechanical dispersion in a general population: Data from the Akershus cardiac examination 1950 study. Eur Heart J Cardiovasc Imaging 2020; 21:183–90.</mixed-citation>
      </ref>
      <ref id="B29">
        <mixed-citation xlink:type="simple">29. Mornos C, Muntean D, Mornos A, et al. Risk stratification in patients with heart failure: The value of considering both global longitudinal left ventricular strain and mechanical dispersion. Can J Physiol Pharmacol 2017; 95:1360–8.</mixed-citation>
      </ref>
      <ref id="B30">
        <mixed-citation xlink:type="simple">30. Matsuzoe H, Tanaka H, Matsumoto K, et al. Left ventricular dyssynergy and dispersion as determinant factors of fatal ventricular arrhythmias in patients with mildly reduced ejection fraction. Eur Heart J Cardiovasc Imaging 2016; 17:334–42.</mixed-citation>
      </ref>
      <ref id="B31">
        <mixed-citation xlink:type="simple">31. Banasik G, Segiet O, Elwart M, et al. LV mechanical dispersion as a predictor of ventricular arrhythmia in patients with advanced systolic heart failure: A pilot study. Herz 2016; 41:599–604.</mixed-citation>
      </ref>
      <ref id="B32">
        <mixed-citation xlink:type="simple">32. Van der Bijl P, Khidir MJH, Leung M, et al. Reduced left ventricular mechanical dispersion at 6 months follow-up after cardiac resynchronization therapy is associated with superior long-term outcome. Heart Rhythm 2018; 15:1683–9.</mixed-citation>
      </ref>
      <ref id="B33">
        <mixed-citation xlink:type="simple">33. Haugaa KH, Edvardsen T, Leren TP, et al. Left ventricular mechanical dispersion by tissue Doppler imaging: A novel approach for identifying high-risk individuals with long QT syndrome. Eur Heart J 2009; 30:330–7.</mixed-citation>
      </ref>
      <ref id="B34">
        <mixed-citation xlink:type="simple">34. Lie ØH, Rootwelt-Norberg C, Dejgaard LA, et al. Prediction of life-threatening ventricular arrhythmia in patients with arrhythmogenic cardiomyopathy: a primary prevention cohort study. JACC Cardiovasc Imaging 2018; 11:1377–86.</mixed-citation>
      </ref>
      <ref id="B35">
        <mixed-citation xlink:type="simple">35. Van Grootel RWJ, Van den Bosch AE, Baggen VJM, et al. The prognostic value of myocardial deformation in adult patients with corrected tetralogy of Fallot. J Am Soc Echocardiogr 2019; 32:866–75.e2.</mixed-citation>
      </ref>
      <ref id="B36">
        <mixed-citation xlink:type="simple">36. Biering-Sørensen T, Knappe D, Pouleur AC, et al. Regional longitudinal deformation improves prediction of ventricular tachyarrhythmias in patients with heart failure with reduced ejection fraction: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy). Circ Cardiovasc Imaging 2017; 10(1):e005096.</mixed-citation>
      </ref>
      <ref id="B37">
        <mixed-citation xlink:type="simple">37. Kosiuk J, Dinov B, Bollmann A, et al. Association between ventricular arrhythmias and myocardial mechanical dispersion assessed by strain analysis in patients with nonischemic cardiomyopathy. Clin Res Cardiol 2015; 104:1072–7.</mixed-citation>
      </ref>
      <ref id="B38">
        <mixed-citation xlink:type="simple">38. Nikoo MH, Zarrabi M, Moaref A, et al. Global longitudinal strain may be the one that appropriately identifies candidates of ICD implantation. Cardiol Res Pract 2024; 16:2214072.</mixed-citation>
      </ref>
      <ref id="B39">
        <mixed-citation xlink:type="simple">39. Kutyifa V, Pouleur AC, Knappe D, et al. Dyssynchrony and the risk of ventricular arrhythmias. JACC Cardiovasc Imaging 2013; 6:432–44.</mixed-citation>
      </ref>
      <ref id="B40">
        <mixed-citation xlink:type="simple">40. Rodríguez-Zanella H, Haugaa K, Boccalini F, et al. Physiological determinants of left ventricular mechanical dispersion: a 2-dimensional speckle tracking echocardiographic study in healthy volunteers. JACC Cardiovasc Imaging 2018; 11:650–1.</mixed-citation>
      </ref>
      <ref id="B41">
        <mixed-citation xlink:type="simple">41. Vassallo JA, Cassidy DM, Kindwall KE, et al. Nonuniform recovery of excitability in the left ventricle. Circulation 1988; 78:1365–72.</mixed-citation>
      </ref>
      <ref id="B42">
        <mixed-citation xlink:type="simple">42. Harapoz M, Zada M, Matthews J, et al. Echocardiographic predictors of ventricular arrhythmias in patients with non-ischemic cardiomyopathy. Int J Cardiol Heart Vasc 2022; 39:100962.</mixed-citation>
      </ref>
      <ref id="B43">
        <mixed-citation xlink:type="simple">43. Kaya E, Andresen K, Lie ØH, et al. Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study. Eur Heart J Cardiovasc Imaging 2024; 25(4):539–47.</mixed-citation>
      </ref>
      <ref id="B44">
        <mixed-citation xlink:type="simple">44. Aryee EK, Ozkan B, Ndumele CE. Heart failure and obesity: the latest pandemic. Prog Cardiovasc Dis 2023; 78:43–8.</mixed-citation>
      </ref>
      <ref id="B45">
        <mixed-citation xlink:type="simple">45. Maisuradze D. Global longitudinal strain in patients with metabolic syndrome and normal ejection fraction. J Cardiol Res Reviews &amp; Reports 2022; SRC/JCRRR-166.</mixed-citation>
      </ref>
      <ref id="B46">
        <mixed-citation xlink:type="simple">46. Torres WM, Jacobs J, Doviak H, et al. Regional and temporal changes in left ventricular strain and stiffness in a porcine model of myocardial infarction. Am J Physiol Heart Circ Physiol 2018; 315(4):H958–H967.</mixed-citation>
      </ref>
      <ref id="B47">
        <mixed-citation xlink:type="simple">47. Luisi GA, Pestelli G, Lorenzoni G, et al. Severe impairment of left ventricular regional strain in STEMI patients is associated with post-infarct remodeling. J Clin Med 2022; 11(18):5348.</mixed-citation>
      </ref>
      <ref id="B48">
        <mixed-citation xlink:type="simple">48. Hoogslag GE, Thijssen J, Höke U, et al. Prognostic implications of left ventricular regional function heterogeneity assessed with two-dimensional speckle tracking in patients with ST-segment elevation myocardial infarction and depressed left ventricular ejection fraction. Heart Vessel 2014; 29:619–28.</mixed-citation>
      </ref>
      <ref id="B49">
        <mixed-citation xlink:type="simple">49. Yan AT, Shayne AJ, Brown KA, et al. Characterization of the peri-infarct zone by contrast-enhanced cardiac magnetic resonance imaging is a powerful predictor of post-myocardial infarction mortality. Circulation 2006; 114:32–9.</mixed-citation>
      </ref>
      <ref id="B50">
        <mixed-citation xlink:type="simple">50. Brainin P. Myocardial postsystolic shortening and early systolic lengthening: current status and future directions. Diagnostics 2021; 11:1428.</mixed-citation>
      </ref>
      <ref id="B51">
        <mixed-citation xlink:type="simple">51. Smiseth OA, Donal E, Penicka M, et al. How to measure left ventricular myocardial work by pressure-strain loops. Eur Heart J Cardiovasc Imaging 2021; 22:259–61.</mixed-citation>
      </ref>
      <ref id="B52">
        <mixed-citation xlink:type="simple">52. Russell K, Eriksen M, Aaberge L, et al. A novel clinical method for quantification of regional left ventricular pressure-strain loop area: A non-invasive index of myocardial work. Eur Heart J 2012; 33:724–33.</mixed-citation>
      </ref>
      <ref id="B53">
        <mixed-citation xlink:type="simple">53. Olsen FJ, Skaarup KG, Lassen MCH, et al. Normal values for myocardial work indices derived from pressure-strain loop analyses: from the CCHS. Circ Cardiovasc Imaging 2022; 15:e013712.</mixed-citation>
      </ref>
      <ref id="B54">
        <mixed-citation xlink:type="simple">54. Truong VT, Vo HQ, Ngo TNM, et al. Normal ranges of global left ventricular myocardial work indices in adults: a meta-Analysis. J Am Soc Echocardiogr 2022; 35:369–77.</mixed-citation>
      </ref>
      <ref id="B55">
        <mixed-citation xlink:type="simple">55. Jaworski K, Firek B, Syska P, et al. Malignant arrhythmia associated with mitral annular disjunction: Myocardial work as a potential tool in the search for a substrate. Kardiol Pol 2022; 80:93–4.</mixed-citation>
      </ref>
      <ref id="B56">
        <mixed-citation xlink:type="simple">56. Hiemstra YL, Van der Bijl P, El Mahdiui M, et al. Myocardial work in nonobstructive hypertrophic cardiomyopathy: implications for outcome. J Am Soc Echocardiogr 2020; 33:1201–8.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
