<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//TaxonX//DTD Taxonomic Treatment Publishing DTD v0 20100105//EN" "https://foliamedica.bg/nlm/tax-treatment-NS0.dtd">
<article xmlns:tp="http://www.plazi.org/taxpub" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">87</journal-id>
      <journal-id journal-id-type="index">urn:lsid:arphahub.com:pub:A116C711-4C18-5A38-8F1E-5E97753A8A64</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Folia Medica</journal-title>
        <abbrev-journal-title xml:lang="en">FM</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0204-8043</issn>
      <issn pub-type="epub">1314-2143</issn>
      <publisher>
        <publisher-name>Plovdiv Medical University</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3897/folmed.68.e161188</article-id>
      <article-id pub-id-type="publisher-id">161188</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Research Article</subject>
        </subj-group>
        <subj-group subj-group-type="scientific_subject">
          <subject>Dental medicine</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Micro-scratch and wear resistance of restorative dental materials: an in vitro study</article-title>
      </title-group>
      <contrib-group content-type="authors">
        <contrib contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Aleksandrova</surname>
            <given-names>Valeriya</given-names>
          </name>
          <email xlink:type="simple">v.aleksandrova@mu-plovdiv.bg</email>
          <uri content-type="orcid">https://orcid.org/0000-0001-8590-8218</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Manchorova</surname>
            <given-names>Neshka</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0001-7822-2752</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Todorova</surname>
            <given-names>Veselina</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0001-5885-6299</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Vangelov</surname>
            <given-names>Lyubomir</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0003-1945-2499</uri>
          <xref ref-type="aff" rid="A1">1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name name-style="western">
            <surname>Alexandrov</surname>
            <given-names>Svetlin</given-names>
          </name>
          <uri content-type="orcid">https://orcid.org/0000-0002-4319-6360</uri>
          <xref ref-type="aff" rid="A2">2</xref>
        </contrib>
      </contrib-group>
      <aff id="A1">
        <label>1</label>
        <addr-line content-type="verbatim">Department of Operative Dentistry and Endodontics, Faculty of Dental Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria</addr-line>
        <institution>Department of Operative Dentistry and Endodontics, Faculty of Dental Medicine, Medical University of Plovdiv</institution>
        <addr-line content-type="city">Plovdiv</addr-line>
        <country>Bulgaria</country>
      </aff>
      <aff id="A2">
        <label>2</label>
        <addr-line content-type="verbatim">Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria</addr-line>
        <institution>Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv</institution>
        <addr-line content-type="city">Plovdiv</addr-line>
        <country>Bulgaria</country>
      </aff>
      <author-notes>
        <fn fn-type="corresp">
          <p><bold>Corresponding author</bold>: Valeriya Aleksandrova, Department of Operative Dentistry and Endodontics, Faculty of Dental Medicine, Medical University of Plovdiv, 3 Hristo Botev Blvd., 4002 Plovdiv, Bulgaria; Email: <email xlink:type="simple">v.aleksandrova@mu-plovdiv.bg</email></p>
        </fn>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2026</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>30</day>
        <month>01</month>
        <year>2026</year>
      </pub-date>
      <volume>68</volume>
      <issue>1</issue>
      <elocation-id>e161188</elocation-id>
      <uri content-type="arpha" xlink:href="http://openbiodiv.net/82059D6D-34D8-506F-937F-75DA8A1B15CA">82059D6D-34D8-506F-937F-75DA8A1B15CA</uri>
      <history>
        <date date-type="received">
          <day>05</day>
          <month>06</month>
          <year>2025</year>
        </date>
        <date date-type="accepted">
          <day>20</day>
          <month>10</month>
          <year>2025</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>Valeriya Aleksandrova, Neshka Manchorova, Veselina Todorova, Lyubomir Vangelov, Svetlin Alexandrov</copyright-statement>
        <license license-type="creative-commons-attribution" xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <abstract>
        <label>Abstract</label>
        <p><bold>Aim</bold>: The study of the tribological properties of dental materials is a growing and rapidly expanding field. The aim of our research is to investigate the micro-scratch and wear resistance of different restorative dental materials.</p>
        <p><bold>Materials and methods</bold>: Three restorative materials indicated for the treatment of dental caries in the distal area of the dentition were used: dental amalgam without γ<sub>2</sub> phase, with high Ag content (Cavex Non Gamma-2); a microhybrid resin-based composite material (Gradia Direct posterior); a metal alloy (Duceralloy C) was used as a positive control. All specimens were subjected to micro-scratch resistance test in 1 N, 5 N, 9 N mode, a ball-on-flat wear resistance test at 120,000/240,000 cycles loaded at 50 N. The examined surfaces of the specimens were visualized by optical microscopy and by 3D profilometry of all the specimens tested after 240,000 wear cycles.</p>
        <p><bold>Results</bold>: The results are presented in the form of graphs - for each specimen, for each individual test, and for each individual cycle. The wear resistance of Duceralloy C increases after 240,000 cycles. The wear resistance of Cavex Non Gamma-2 and Gradia Direct posterior decreases with increasing time and friction cycles.</p>
        <p><bold>Conclusion</bold>: The results of this study may help to elucidate the wear mechanisms and provide additional information on the expected changes in the materials tested in clinical practice.</p>
      </abstract>
      <kwd-group>
        <label>Keywords</label>
        <kwd>3D profilometry</kwd>
        <kwd>ball-on-flat test</kwd>
        <kwd>dental tribology</kwd>
        <kwd>micro-scratch test</kwd>
        <kwd>restorative dental materials</kwd>
        <kwd>micro-scratch test</kwd>
      </kwd-group>
    </article-meta>
    <notes>
      <sec sec-type="Citation" id="sec1">
        <title>Citation</title>
        <p>Aleksandrova V, Manchorova N, Todorova V, Vangelov L, Alexandrov S. Micro-scratch and wear resistance of restorative dental materials: an in vitro study. Folia Med (Plovdiv) 2026;68(1):е161188. <ext-link ext-link-type="doi" xlink:href="10.3897/folmed.68.e161188">doi: 10.3897/folmed.68.e161188</ext-link>.</p>
      </sec>
    </notes>
  </front>
  <body>
    <sec sec-type="Introduction" id="sec2">
      <title>Introduction</title>
      <p>Tribology is the science and engineering of interactive surfaces, involving the study and application of the principles of friction, lubrication and wear.<sup>[<xref ref-type="bibr" rid="B1">1</xref>]</sup> Tribological studies range from theoretical to experimental and from basic to applied research, covering aspects from the nano- to the microscopic world.<sup>[<xref ref-type="bibr" rid="B2">2</xref>]</sup> The examination of the tribological properties of dental materials is a growing and rapidly expanding field. Intensive research has been carried out to understand the importance and applicability of dental tribology for the selection of dental materials for the treatment of carious lesions in a high-stress region.<sup>[<xref ref-type="bibr" rid="B3">3</xref>]</sup></p>
      <p>It is recognized that tooth wear is a clinical problem that is becoming increasingly important in ageing populations. The frequency of parafunctional patients in the world population has increased. According to most literature sources, the prevalence of adults exhibiting some periods of bruxism ranges from 6% to 20%.<sup>[<xref ref-type="bibr" rid="B4">4</xref>]</sup></p>
      <p>The main problem involved in the dental application of resin-based composite materials is their inadequate wear resistance when used as posterior composite restorations under extreme masticatory forces.<sup>[<xref ref-type="bibr" rid="B5">5</xref>]</sup> Despite improvements in the mechanical properties of composite resins, wear is still a major problem, especially in patients with parafunctional activities.<sup>[<xref ref-type="bibr" rid="B6">6</xref>]</sup></p>
    </sec>
    <sec sec-type="Aim" id="sec3">
      <title>Aim</title>
      <p>The objective of our research is to study the micro-scratch and wear resistance of different restorative dental materials.</p>
      <p>The working hypothesis for this study was that the three restorative dental materials would exhibit different tribological behavior, with the metal alloy (control) having the highest wear and scratch resistance and the resin-based composite having the lowest.</p>
    </sec>
    <sec sec-type="materials|methods" id="sec4">
      <title>Materials and methods</title>
      <p>Three restorative dental materials were used: a dental amalgam without γ<sub>2</sub> phase, with a high Ag content (Cavex Non Gamma-2); a microhybrid resin-based composite material (Gradia Direct Posterior); a metal alloy (Duceralloy C) was used as a positive control. The test materials are indicated for distal restorations in operative dentistry.</p>
      <p>An original experimental model was used for the purposes of the present study. Its preparation has already been described in our previous research.<sup>[<xref ref-type="bibr" rid="B7">7</xref>]</sup> Metal plates measuring 50×50 mm and 3 mm thick were manufactured as standard carriers. Each was sliced into 9 holes measuring 10 mm in diameter and 1.5 mm in depth. The corresponding test substance was applied to the apertures.</p>
      <p>The retention of the composite test materials in the cut-out sockets of the metal plates was further reinforced by the metal primer (Metal Primer-2, GC Corporation, Tokyo, Japan). Composite specimens were cured incrementally with an LED light unit (Mini LED Satelec, Switzerland), then finished and polished with fine-grit.</p>
      <p>Dental amalgam capsules were mixed in duration and frequency in accordance with the manufacturer’s recommendations. Dental amalgam was placed and condensed according to well known methods. The amalgam samples were polished after 24 hours of settling.</p>
      <p>Positive control group specimens were made and cast from a metal alloy containing no nickel. The fixation of the metal alloy control tribological discs was performed by means of a prepared matrix form of additive silicone (Ormaplus, Major, Italy). The parameters of the standard metal plate were used. Using an epoxy resin prepared according to the manufacturer’s requirements, metal test discs of the control study were fixed. The composition of Duceralloy C included Co (59.4%), Cr (24.5%), W (10%), Nb (2%), V (2%), Si (1%), Mo (1%), Fe (0.1%). This composition provides high hardness and corrosion resistance.</p>
      <p>The design of the study <bold>(Fig. <xref ref-type="fig" rid="F1">1</xref>)</bold> is identical to that of our previous paper.<sup>[<xref ref-type="bibr" rid="B7">7</xref>]</sup> For each material type, the three specimens from the first column are tested for scratch resistance in the 1 N, 5 N, and 9 N mode. The three specimens from the second column are tested for ball-on-flat friction resistance for 120,000 cycles at 50 N load. The three specimens from the last column are tested for ball-on-flat friction resistance for 240,000 cycles at 50 N load.</p>
      <fig id="F1">
        <object-id content-type="arpha">8C0545D4-1033-5B57-8FE0-B84AB630F534</object-id>
        <caption>
          <p><bold>Figure 1.</bold> Design of the study</p>
        </caption>
        <graphic xlink:href="foliamedica-68-1-e161188-g001.jpg" id="oo_1524130.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/1524130</uri>
        </graphic>
      </fig>
      <p>As in our previous study<sup>[<xref ref-type="bibr" rid="B7">7</xref>]</sup>, the test instrument used in this investigation is UMT-2M (Bruker-CETR) <bold>(Fig. <xref ref-type="fig" rid="F2">2</xref>)</bold>. This universal modular device can perform a wide range of macro- and micro-mechanical and tribological tests on coatings (thin or thick, hard or soft) and bulk materials such as ceramics, polymers, glass, composites, fabrics, and paper. It operates with loads from 5 mN to 1000 N, allows the use of multiple sensors and provides simultaneous measurement, visualisation and real-time recording of deformations and forces while performing synchronized linear and rotary displacements in different axes using a synchronized linear or rotary drive. A servo control mechanism is used to achieve high precision motion and load control.</p>
      <fig id="F2">
        <object-id content-type="arpha">01ABA047-8686-51FD-98D4-59235A4AD106</object-id>
        <caption>
          <p><bold>Figure 2.</bold> UMT-2M (Bruker-CETR)</p>
        </caption>
        <graphic xlink:href="foliamedica-68-1-e161188-g002.jpg" id="oo_1524131.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/1524131</uri>
        </graphic>
      </fig>
      <p>The mode and conditions of the micro-scratch test procedure included a cycle of three steps in which multiple scratches were performed with a distance of 1 mm between each two scratches, and the length of each scratch was 5 mm. The test was performed with three constant forces (1 N, 5 N, and 9 N) for each of the five samples. The translational movement of the scratch was performed by a linear drive on which the samples were fixed at a speed of 0.1 mm/sec. The lateral movement of 1 mm distance when performing successive scratches was realized by a slider that moved the head with the cutter. The tests were carried out in accordance with the ASTM G133-95 standard.</p>
      <p>The ball-on-flat wear tests used a 6.35 mm diameter chromium-plated steel ball, which was slid over the surface of a fixed specimen under the influence of a reciprocating motion of a linear actuator. The apparatus monitors and records the dynamic normal load, frictional force, and coefficient of friction.</p>
      <p>Tests to determine the coefficient of friction of dental samples were carried out under the same conditions and in accordance with the standards as follows:</p>
      <list list-type="bullet">
        <list-item>
          <p>speed of ball movement on the surface: 2.5 mm/sec;
</p>
        </list-item>
        <list-item>
          <p>applied constant force: 50 N;
</p>
        </list-item>
        <list-item>
          <p>friction test duration: 2 times for 30 minutes;
</p>
        </list-item>
        <list-item>
          <p>temperature of 24°C;
</p>
        </list-item>
        <list-item>
          <p>humidity: 40%.
</p>
        </list-item>
      </list>
      <p>3D profilometry was performed using a Zeta-20 optical 3D profilometer (Zeta Instruments) with vertical (Z) resolution &lt;1 nm, field of view from 0.006 mm<sup>2</sup> to 15 mm<sup>2</sup> and magnifications of 5×, 20×, 50×, and 100×.</p>
      <p>Data were analyzed with IBM SPSS Statistics for Windows, version 27.0 (IBM Corp., Armonk, NY, USA). Statistical analysis was performed using descriptive statistics (mean ± <italic>SD</italic>). Comparisons between groups were made using one-way ANOVA, with <italic>p</italic>&lt;0.05 considered significant.</p>
    </sec>
    <sec sec-type="Results" id="sec5">
      <title>Results</title>
      <p><bold>Table <xref ref-type="table" rid="T1">1</xref></bold> displays the micro-scratch test average results.</p>
      <table-wrap id="T1" position="float" orientation="portrait">
        <caption>
          <p><bold>Table 1</bold>. Average values for the coefficient of friction and the depth of the micro-scratches as a function of the load applied </p>
        </caption>
        <table>
          <tbody>
            <tr>
              <td rowspan="1" colspan="1">
                <bold>Samples</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Dental material</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Load (N)</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Coefficient of friction</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Depth of micro-scratch (µм)</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="3" colspan="1">1</td>
              <td rowspan="3" colspan="1">Duceralloy C</td>
              <td rowspan="1" colspan="1">1</td>
              <td rowspan="1" colspan="1">0.3347</td>
              <td rowspan="1" colspan="1">46.79</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">5</td>
              <td rowspan="1" colspan="1">0.5097</td>
              <td rowspan="1" colspan="1">26.54</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">9</td>
              <td rowspan="1" colspan="1">0.7307</td>
              <td rowspan="1" colspan="1">51.76</td>
            </tr>
            <tr>
              <td rowspan="3" colspan="1">3</td>
              <td rowspan="3" colspan="1">Gradia Direct Posterior</td>
              <td rowspan="1" colspan="1">1</td>
              <td rowspan="1" colspan="1">0.4953</td>
              <td rowspan="1" colspan="1">30.71</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">5</td>
              <td rowspan="1" colspan="1">0.7599</td>
              <td rowspan="1" colspan="1">28.21</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">9</td>
              <td rowspan="1" colspan="1">0.8315</td>
              <td rowspan="1" colspan="1">40.23</td>
            </tr>
            <tr>
              <td rowspan="3" colspan="1">4</td>
              <td rowspan="3" colspan="1">Cavex Alloy</td>
              <td rowspan="1" colspan="1">1</td>
              <td rowspan="1" colspan="1">0.1883</td>
              <td rowspan="1" colspan="1">7.66</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">5</td>
              <td rowspan="1" colspan="1">0.3213</td>
              <td rowspan="1" colspan="1">14.29</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">9</td>
              <td rowspan="1" colspan="1">0.5412</td>
              <td rowspan="1" colspan="1">20.11</td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
      <p>The results of the micro-scratch tests are presented by graphs for each specimen, and for each individual test <bold>(Fig. <xref ref-type="fig" rid="F3">3</xref>)</bold></p>
      <fig id="F3">
        <object-id content-type="arpha">98B13F4D-BCB9-5785-92FD-73228478F0A6</object-id>
        <caption>
          <p><bold>Figure 3.</bold> Graphical representation of coefficient of friction and depth of micro-scratch results from three consecutive tests in the same direction. Applied force of 9 N; speed of 0.1 mm/sec, and scratch length of 5 mm; <bold>A</bold>. Cavex Non Gamma-2; <bold>B</bold>. Gradia Direct Posterior; <bold>C</bold>. Duceralloy C.</p>
        </caption>
        <graphic xlink:href="foliamedica-68-1-e161188-g003.jpg" id="oo_1524132.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/1524132</uri>
        </graphic>
      </fig>
      <p>As shown in <bold>Table <xref ref-type="table" rid="T1">1</xref></bold>, the metal alloy (Duceralloy C) presented the lowest coefficient of friction at low loads, though with higher scratch depth at 1 N compared to the amalgam. Cavex Non Gamma-2 demonstrated the shallowest scratch depths, while Gradia Direct Posterior exhibited consistently higher friction coefficients, peaking at 9 N. <bold>Fig. <xref ref-type="fig" rid="F3">3</xref></bold> illustrates these results, showing more stable performance for the alloy than the composite.</p>
      <p>The results of the wear resistance tests for each sample as well as for each individual test and each individual cycle of each test are also presented graphically <bold>(Fig. <xref ref-type="fig" rid="F4">4</xref>)</bold>. <bold>Fig. <xref ref-type="fig" rid="F4">4</xref></bold> shows the wear resistance trends: the composite showed progressive degradation across cycles, the amalgam intermediate resistance, and the alloy improved resistance over time, likely due to friction-induced hardening.</p>
      <fig id="F4">
        <object-id content-type="arpha">8050C50C-6040-5A6B-B5F0-AEB2085EB155</object-id>
        <caption>
          <p><bold>Figure 4.</bold> Graphic representation of the reported results during the second 30 minutes of the ball-on-flat test; <bold>A.</bold> Cavex Non Gamma-2; <bold>B.</bold> Gradia Direct Posterior; <bold>C.</bold> Duceralloy C</p>
        </caption>
        <graphic xlink:href="foliamedica-68-1-e161188-g004.jpg" id="oo_1524133.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/1524133</uri>
        </graphic>
      </fig>
      <p>From <bold>Table <xref ref-type="table" rid="T2">2</xref></bold> it can be summarized that the micro-scratch depth values of the positive control Duceralloy C after the first 30 minutes (120,000 cycles) of wear are higher than those after the second 30 minutes (240,000 cycles). For the Cavex Non Gamma-2 specimen tested, the wear resistance decreased over time. The micro-hybrid composite showed a lower wear resistance, which decreased with increasing time and friction cycles (13 µm after 30 min/120,000 cycles; 18 µm after 60 min/240,000 cycles).</p>
      <table-wrap id="T2" position="float" orientation="portrait">
        <label>Table 2.</label>
        <caption>
          <p>Average values for the coefficient of friction and the depth of micro-scrach for each of the two 30-minute wear cycles for each specimen</p>
        </caption>
        <table>
          <tbody>
            <tr>
              <td rowspan="1" colspan="1">
                <bold>Samples</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Dental material</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Load (N)</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Average coefficient of friction</bold>
              </td>
              <td rowspan="1" colspan="1">
                <bold>Depth of micro-scratch (µм)</bold>
              </td>
            </tr>
            <tr>
              <td rowspan="2" colspan="1">1</td>
              <td rowspan="2" colspan="1">Duceralloy C</td>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.3568</td>
              <td rowspan="1" colspan="1">8</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.3208</td>
              <td rowspan="1" colspan="1">1.5</td>
            </tr>
            <tr>
              <td rowspan="2" colspan="1">2</td>
              <td rowspan="2" colspan="1">Cavex non Gamma-2</td>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.1619</td>
              <td rowspan="1" colspan="1">4</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.2219</td>
              <td rowspan="1" colspan="1">7</td>
            </tr>
            <tr>
              <td rowspan="2" colspan="1">3</td>
              <td rowspan="2" colspan="1">Gradia Direct Рosterior</td>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.5501</td>
              <td rowspan="1" colspan="1">13</td>
            </tr>
            <tr>
              <td rowspan="1" colspan="1">50</td>
              <td rowspan="1" colspan="1">0.614</td>
              <td rowspan="1" colspan="1">18</td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
      <p>The examined surfaces of the test specimens were visualised by optical microscopy after micro-scratch and friction testing and by 3D profilometry of all test specimens after 240,000 wear cycles <bold>(Fig. <xref ref-type="fig" rid="F5">5</xref>)</bold>.</p>
      <fig id="F5">
        <object-id content-type="arpha">944CBC19-19D2-56C5-AF9C-754B01EB00D1</object-id>
        <caption>
          <p><bold>Figure 5</bold>. 3D profilometry; <bold>A</bold>. Cavex Non Gamma-2; <bold>B</bold>. Gradia Direct Posterior; <bold>C</bold>. Duceralloy C.</p>
        </caption>
        <graphic xlink:href="foliamedica-68-1-e161188-g005.jpg" id="oo_1524134.jpg">
          <uri content-type="original_file">https://binary.pensoft.net/fig/1524134</uri>
        </graphic>
      </fig>
      <p>Due to the high hardness and homogeneous composition of the metal control, these samples exhibit a pronounced but uniform surface roughness. In the dental amalgam samples tested, the surface roughness is less pronounced, since the amalgam is softer than the metal, but micropores are observed due to the phase crystallization. Despite the inorganic phases, each of them has a different hardness and wear resistance. Insufficient condensation and polishing in the test specimens’ preparation is another probable reason for micropores. The Ag percentage in the composition of Cavex Non Gamma-2 is significantly higher. This is due to the more uniform surface roughness, which is close to that of the metal control. The surface roughness of the resin-based composite studied is less pronounced than that of the metal alloy. It has multiple micropores. The logical explanation for this is the fact that it is composed of two different natural phases, organic and inorganic, which have very different mechanical properties.</p>
    </sec>
    <sec sec-type="Discussion" id="sec6">
      <title>Discussion</title>
      <p>In tribology, the surface of a body is defined as the interface of the body with the environment, which differs in structure and properties from those of its internal parts. The quality of surfaces largely determines functional characteristics such as fatigue, wear resistance, friction, and corrosion resistance of materials, which in turn determine the indications for their use. The surface roughness of direct composite restorations is important for their durability as it reflects the interaction of the restorative materials with the oral environment. Rough, unpolished restorations increase the coefficient of friction and can increase the rate of wear.<sup>[<xref ref-type="bibr" rid="B8">8</xref>]</sup></p>
      <p>The results obtained indicate a high roughness of the specimens tested. It can be concluded that in clinical conditions, it is even more difficult to achieve optimal smoothness of the surface of restorations. This affects their mechanical behaviour, especially under conditions of extreme masticatory forces. A large number of laboratory studies on the wear resistance of dental restorative materials are described in the available specialised scientific database.<sup>[<xref ref-type="bibr" rid="B9">9</xref>-<xref ref-type="bibr" rid="B13">13</xref>]</sup> In these studies, various types of devices were used to simulate tooth wear with the participation of two bodies (two-body wear) or with the participation of three bodies (three-body wear). With the help of these devices, the conditions in the oral cavity are reproduced as closely as possible. Potentially, materials such as enamel, gold, ceramics, composites, that simulate the in vitro antagonist, can be used.</p>
      <p>No data were found for the study of the wear resistance of dental restorative materials with the measuring device we used – UMT-2M (Bruker-CETR), which by its nature is not an instrument for simulating tooth wear, but a universal modular instrument for tribological testing. This measuring device is used in scientific research on various materials such as ceramics, metals, polymers, glass, composites, which are not used for dental purposes.<sup>[<xref ref-type="bibr" rid="B14">14</xref>,<xref ref-type="bibr" rid="B15">15</xref>]</sup> The results obtained in the course of our study are not comparable with the laboratory tests cited in the dental scientific literature, due to the specific measuring equipment and the differences in methodology (load force, number of cycles, duration).</p>
      <p>In our previous research, we found an analogy with scientific research on the tribological properties of polymer-based materials, which are not applied in the dental field.<sup>[<xref ref-type="bibr" rid="B7">7</xref>,<xref ref-type="bibr" rid="B14">14</xref>,<xref ref-type="bibr" rid="B15">15</xref>]</sup></p>
      <p>The observed improvement in wear resistance of the metal alloy during prolonged testing may be explained by friction-induced temperature rise, which leads to surface hardening of the alloy. This phenomenon has been described in tribological studies of metal alloys and is consistent with our findings.<sup>[<xref ref-type="bibr" rid="B16">16</xref>]</sup></p>
      <p>3D profilometry is a fast, non-contact and objective method that provides information about the topography and roughness of the objects under investigation. It can be used to obtain both topographic and quantitative data, which explains its wide application in a number of medical fields. In dentistry, 3D profilometry is mainly used to study the abrasion resistance of hard dental tissues and different types of restorative materials such as dental composites, glass-ionomer cements, and dental ceramics.<sup>[<xref ref-type="bibr" rid="B17">17</xref>]</sup></p>
    </sec>
    <sec sec-type="Conclusions" id="sec7">
      <title>Conclusions</title>
      <p>Within the limitations of this in vitro study, we conclude that material composition and surface roughness significantly affect wear resistance and scratch behavior of restorative dental materials. The metal alloy demonstrated the highest resistance, followed by the amalgam, while the resin composite showed the least favorable performance. These results emphasize the importance of material selection in clinical situations involving high occlusal stress and parafunctional habits.</p>
      <p>There are studies confirming that in vitro wear simulation is extremely valuable in the screening of new restorative dental materials. Results in this area will elucidate the mechanisms of wear and provide additional information on the expected changes in the materials under investigation in clinical practice.</p>
    </sec>
    <sec sec-type="Funding" id="sec8">
      <title>Funding</title>
      <p>The authors have no funding to report.</p>
    </sec>
    <sec sec-type="Competing interests" id="sec9">
      <title>Competing interests</title>
      <p>The authors have declared that no competing interests exist.</p>
    </sec>
  </body>
  <back>
    <ack>
      <title>Acknowledgements</title>
      <p>The authors have no support to report.</p>
    </ack>
    <ref-list>
      <title>References</title>
      <ref id="B1">
        <mixed-citation>1. Zheng Y, Bashandeh K, Shakil A, et al. Review of dental tribology: Current status and challenges. Tribol Int 2022; 166:107354. <ext-link ext-link-type="doi" xlink:href="10.1016/j.triboint.2021.107354">doi: 10.1016/j.triboint.2021.107354</ext-link></mixed-citation>
      </ref>
      <ref id="B2">
        <mixed-citation>2. Ciulli E. Vastness of tribology research fields and their contribution to sustainable development. Lubricants 2024; 12(2):33.</mixed-citation>
      </ref>
      <ref id="B3">
        <mixed-citation>3. Zhou ZR, Zheng J. Tribology of dental materials: a review. Journal of physics D: applied physics. 2008 May 13;41(11):113001. <ext-link ext-link-type="doi" xlink:href="10.1088/0022-3727/41/11/113001">doi: 10.1088/0022-3727/41/11/113001</ext-link></mixed-citation>
      </ref>
      <ref id="B4">
        <mixed-citation>4. Laluque JF, Brocard D, d<sup>'</sup>Incau E. Understanding of bruxism. Current knowledge and practice. Quintessence Int 2017.</mixed-citation>
      </ref>
      <ref id="B5">
        <mixed-citation>5. Lavigne G, Montplaisir J. Bruxism: epidemiology, diagnosis pathophysiology and pharmacology. Adv Pain Res Therapy 1995; 21:387–92.</mixed-citation>
      </ref>
      <ref id="B6">
        <mixed-citation>6. Dionysopoulos D, Gerasimidou O. Wear of contemporary dental composite resin restorations: a literature review. Restor Dent Endod 2021; 46(2):e18.</mixed-citation>
      </ref>
      <ref id="B7">
        <mixed-citation>7. Aleksandrova V, Manchorova N, Aleksandrov S. Tribological tests of resine-based composite materials: a design study. J of IMAB 2021; 27(2):3700–6. <ext-link ext-link-type="doi" xlink:href="10.5272/jimab.2021272.3700">doi: 10.5272/jimab.2021272.3700</ext-link></mixed-citation>
      </ref>
      <ref id="B8">
        <mixed-citation>8. Ghinea R, Ugarte-Alvan L, Yebra A, et al. Influence of surface roughness on the color of dental-resin composites. J Zhejiang Univ Sci B, 2011; 12:552–62. <ext-link ext-link-type="doi" xlink:href="10.1631/jzus.B1000374">doi: 10.1631/jzus.B1000374</ext-link></mixed-citation>
      </ref>
      <ref id="B9">
        <mixed-citation>9. Condon JR, Ferracane JL. Evaluation of composite wear with a new multi-made oral wear simulator. Dent Mater 1996; 12(4):218–26.</mixed-citation>
      </ref>
      <ref id="B10">
        <mixed-citation>10. Condon JR, Ferracane JL. In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res 1997; 76(7):1405–11.</mixed-citation>
      </ref>
      <ref id="B11">
        <mixed-citation>11. Frankenberger R, García-Godoy F, Lohbauer U, et al. Evaluation of resin composite materials. Part I: in vitro investigations. Am J Dent 2005; 18(1):23–7.</mixed-citation>
      </ref>
      <ref id="B12">
        <mixed-citation>12. Kawai K, Leinfelder KF. In vitro evaluation of OCA wear resistance of posterior composites. Dent Mater 1995; 11(4):246–51.</mixed-citation>
      </ref>
      <ref id="B13">
        <mixed-citation>13. Manhart J, Kunzelmann KH, Chen HY, et al. Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater 2000; 16(1):33–40.</mixed-citation>
      </ref>
      <ref id="B14">
        <mixed-citation>14. Borovanska I, Ivanov E, Kotsilkova R, et al. Tribological measurements of polypropylene nanocomposites by scratch and friction tests. Tribol J Bultrib 2013; 3:226–35.</mixed-citation>
      </ref>
      <ref id="B15">
        <mixed-citation>15. Petrova I, Ivanov E, Kotsilkova R, et al. Applied study on mechanics of nanocomposites with carbon nanofillers. J Theoret Appl Mech Sofia 2013; 43(3):67–76.</mixed-citation>
      </ref>
      <ref id="B16">
        <mixed-citation>16. Jiang J, Xin B, Zhang A, et al. High-temperature tribological performance of Co45Fe20Cr15W15Si5 complex concentrated alloy: Evolution of multiscale microstructure and friction-induced in-situ oxide layer. J Mater Res Technol 2025; 38;710–17.</mixed-citation>
      </ref>
      <ref id="B17">
        <mixed-citation>17. Fleminga GJP, Reillya Е, Dowlinga АН, et al. Data acquisition variability using profilometry to produce accurate mean total volumetric wear and mean maximum wear depth measurements for the OHSU oral wear simulator. Dent Mater 2016; 32(8):176–84.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>