Invited Review |
|
Corresponding author: Aglika Byandova ( abyandova@pathophysiology.info ) © 2026 Aglika Byandova, Blagoy Marinov.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Byandova A, Marinov B (2026) Cardiopulmonary exercise testing in children: application and interpretation challenges. Folia Medica 68(4): e192711. https://doi.org/10.3897/folmed.68.e192711
|
Abstract
Cardiopulmonary exercise testing (CPET) is a complex functional test that allows for dynamic monitoring of the cardiovascular and respiratory systems during progressive incremental physical activity. CPET is well-established in adult patients, as it provides diagnostic and prognostic value. Pediatric CPET proves informative, although it entails numerous challenges, stemming from the developmental characteristics of children, as well as factors regarding test conduction and interpretation.
Pediatric CPET applicability ranges from estimating exercise capacity in healthy and athletic children to diagnosis and prognosis in cases of chronic disease, such as respiratory or cardiovascular conditions. It can be used as a basis for the assessment of functional capacity in cases of asthma and cystic fibrosis, as well as quality of life scoring in kids with chronic heart failure. Furthermore, exercise testing is used as part of the indirect bronchoprovocation procedures for pulmonary function testing.
Main challenges include the lack of standardized reference values, protocol selection, and the need for special pediatric equipment, as well as the high cost associated with the test.
CPET represents a valuable and increasingly utilized tool for assessment of the pediatric population. Future studies should focus on establishing normative datasets and improving methodological standardization.
cardiopulmonary exercise testing, children, exercise, pediatric
Cardiopulmonary exercise testing (CPET) allows for the simultaneous evaluation of cardiovascular, respiratory, and metabolic responses during progressive incremental physical activity. CPET provides insight into the integrated physiological response to exercise and enables identification of the dominant mechanism of exercise limitation-cardiac, pulmonary, peripheral, or mixed. This places it at the center of modern functional diagnostics.
Recently the CPET application has expanded to include more actively the pediatric population. Childhood is characterized by rapid growth and developmental changes that significantly affect cardiovascular, respiratory, and muscular function. In this context the assessment of functional capacity at rest is often insufficient and does not reflect the real capabilities of the body.
Conducting and interpreting pediatric CPET presents specific challenges related to developmental physiology, protocol, and ergometer selection and safety considerations as well as motivational factors. This review summarizes the principles, clinical applications, and current challenges of CPET in the pediatric population.
Age-related differences in cardiorespiratory response and peripheral muscle utilization lead to specific patterns of adaptation in children during exercise. This requires a careful individual approach to analyzing and interpreting the results of CPET in children.
Children have higher heart rate (HR), both at rest and during physical activity.[
Children and adolescents have lower tidal volume (Vt), higher respiratory rate (RR), and relatively lower mechanical efficiency of breathing compared to adults.[
Young children have a predominance of type 1 “fast” oxidative muscle fibers, which is consistent with a predominantly aerobic physiology.[
VO2 is the primary indicator of aerobic metabolic capacity. It reflects the interaction between pulmonary ventilation, cardiovascular transport, and peripheral utilization of oxygen in the working muscles and is considered the “gold standard” for assessing the aerobic capacity of the individual. VO2 increases linearly with workload increase until the maximal value (VO2max) is reached.[
Ventilatory thresholds are key metabolic points during exercise that mark the characteristic changes in the metabolic processes for energy production required for muscle contraction. The first ventilatory threshold (VT1), also called the anaerobic threshold (AT), reflects the beginning of additional CO2 production, which is an expression of the increasing reliance on anaerobic metabolic pathways. This is accompanied by the incipient development of metabolic acidosis. The second ventilatory threshold (VT2), called by Wasserman the respiratory compensation point (RCP), marks the moment of a disproportionate increase in ventilation relative to CO2 production and is associated with the exhaustion of the compensatory mechanisms for maintaining normal acid-base balance.[
In children, ventilatory thresholds often occur at a relatively higher percentage of VO2peak compared to adults. This is thought to be related to developmental differences in muscle metabolism, including low glycolytic enzyme activity, reduced lactate production, and a greater reliance on oxidative pathways during exercise.[
The respiratory exchange ratio (RER), defined as the ratio of carbon dioxide production to oxygen consumption (VCO2/VO2), reflects substrate utilization during exercise. At rest and during low-intensity exercise, RER values are typically below 1.0, indicating predominant fat oxidation. With increasing exercise intensity and greater reliance on carbohydrate metabolism, RER rises and may exceed 1.0 due to additional CO2 production from buffering of exercise-induced metabolic acidosis.
In pediatric populations, peak RER values during maximal exercise are often lower than those observed in adults.[
The relationship between minute ventilation (VE) and carbon dioxide production (VCO2) is referred to as ventilatory efficiency (VE/VCO2). The ventilatory efficiency slope is typically calculated using linear regression of VE against VCO2 from the onset of exercise until VT2/RCP[
Relationship between VE and VCO2 during incremental exercise, illustrating the VE/VCO2 slope. The solid line represents higher ventilatory efficiency, whereas the dotted line – lower ventilatory efficiency
In children, developmental characteristics including higher RR, smaller Vt, and different lung mechanics can affect the absolute values of the VE/VCO2 slope. Therefore, the use of age-, sex- and height-specific reference values is essential. The ventilatory efficiency slope is informative even at submaximal effort, which makes it a suitable parameter for assessment in individuals who cannot achieve maximum exercise.[
Oxygen uptake efficiency (OUE) reveals the relationship between VO2 and VE during incremental physical activity. This metric is based on the logarithmic relationship between the two parameters, which is graphically expressed by a regression slope, known as the oxygen uptake efficiency slope (OUES).[
Relationship between VO2 and the logarithm of VE during progressive incremental exercise, known as the oxygen uptake efficiency slope (OUES). The solid line represents higher OUES, while the dotted line – lower OUES.
VO2 = a × log10VE + b (Equ. 1)
A significant advantage of oxygen uptake efficiency slope is its relative independence from the test duration and the achievement of maximum effort.[
In children, OUES gains additional significance since the normal values of most CPET parameters are significantly influenced by age and body composition. The use of OUES, especially when calculated to body surface area, allows for better comparability between different age groups. This makes it a valuable tool for assessing cardiorespiratory function in both healthy and diseased children.[
Maximal effort during CPET is typically confirmed by a combination of physiological indicators. A classical marker is the establishment of a VO2 plateau defined as the inability of VO2 to increase with more than 150 ml/min or 2 ml.kg−1.min−1 despite a further increase in the workload.[
In children, determining whether maximal effort was achieved may be even more challenging due to both physiological and behavioral factors. Developmental differences in the cardiovascular, respiratory, and metabolic responses to exercise influence the typical maximal effort markers. Children often demonstrate lower lactate levels even at peak exercise[
When conducting pediatric CPET, careful consideration must be given to both equipment and exercise protocol selection. The child’s height is important when choosing the correct ergometer. Most manufacturers of cycle ergometers require a minimum patient height of 120 cm. Bearing in mind that according to the World Health Organization (WHO), the average height of a preschool-aged child (5 years old) is 111 cm for boys and 109 cm for girls[
Protocol selection needs to consider the child’s age, height, weight, motor coordination, and level of physical training. Ramp protocols provide a more gradual workload increase, which may allow for a more precise determination of the ventilatory thresholds. However, step protocols may be preferable in cases when steady-state measurements are required or when evaluating submaximal responses.[
Protocol design may influence key parameters such as ventilatory efficiency and oxygen uptake kinetics, highlighting the need for standardization in pediatric CPET protocols. Standardized treadmill protocols may prove too difficult and lengthy for very young children. In such cases, the use of modified protocols, such as the modified Bruce treadmill protocol for children[
Maintaining attention and following the examiner’s instructions for a prolonged period of time is often challenging for very young kids. Most treadmill step protocols (Bruce) utilize 3-minute steps in order to allow for adaptation and the achievement of a steady state.[
CPET is generally considered a safe method for diagnostic assessment when performed by trained personnel in an appropriate laboratory setting.[
Absolute contraindications to CPET in children are largely the same as those in adults (Table
Absolute and relative contraindications for CPET. Adapted from ATS/ACCP Statement on Cardiopulmonary exercise testing.[
| Absolute contraindications for CPET | Relative contraindications for CPET |
| Acute myocardial infarction (3–5 days) | Left main coronary stenosis or its equivalent |
| Unstable angina | Moderate stenotic valvular heart disease |
| Uncontrolled arrhythmias causing symptoms or hemodynamic compromise | Severe untreated arterial hypertension at rest or hemodynamic compromise (systolic BP >200 mmHg, diastolic BP >120 mmHg) |
| Syncope | Tachyarrhythmias or bradyarrhythmias |
| Active endocarditis | High‐degree atrioventricular block |
| Acute myocarditis or pericarditis | Hypertrophic cardiomyopathy |
| Symptomatic severe aortic stenosis | Significant pulmonary hypertension |
| Uncontrolled heart failure | Advanced or complicated pregnancy |
| Acute pulmonary embolus or pulmonary infarction | Electrolyte abnormalities |
| Thrombosis of lower extremities | Orthopedic impairment that compromises exercise performance |
| Suspected dissecting aneurysm | |
| Uncontrolled asthma | |
| Pulmonary oedema | |
| Room air desaturation at rest <85% | |
| Respiratory failure | |
| Acute non‐cardiopulmonary disorder that may affect exercise performance or be aggravated by exercise (infection, renal failure, thyrotoxicosis, etc.) | |
| Mental impairment leading to inability to cooperate |
Monitoring during CPET is essential to ensure patient safety. Careful evaluation of the child’s condition should include monitoring for signs of dizziness, severe dyspnea, cyanosis, chest pain, pallor, or loss of coordination.[
CPET provides ample opportunities for diagnosis, monitoring and prognosis in children with an array of cardiovascular or respiratory pathology. The test compliments the classical clinical examination, giving a more in-depth picture regarding the functional state of the individual.
Assessment of physical fitness in children is an important component of pediatric health evaluation, since cardiorespiratory fitness is strongly associated with health outcomes later in life.[
Obesity is a condition associated with the accumulation of excessive adipose tissue and high body mass index (BMI). Childhood obesity proves difficult to manage and leads to numerous complications, including reduced exercise capacity. Obese children have a shorter CPET duration and reach lower values of VO2peak, as well as report higher levels of subjective symptoms of exertion.[
CPET can be used both as a means for assessment, and for monitoring obese children during weight loss regimens and assessing their progress regarding functional parameters, as well as program compliance.[
CPET proves useful in assessing the functional status of children with asthma, cystic fibrosis (CF), exercise-induced bronchoconstriction (EIB), or dyspnea of unknown origin. In the presence of functional airway obstruction, CPET can objectify the degree of airflow limitation during exercise.[
Multiple studies have shown kids with bronchial asthma to have a lower exercise capacity, including lower VO2peak, lower ventilatory efficiency, and lower breathing reserve (BR) compared to healthy controls. There is a positive correlation between lower VO2peak values, poor ventilatory efficiency, and higher BMI in kids.[
CPET can be implemented as a prognostic tool in children with chronic respiratory conditions. In case of CF, VO2peak decline over time has been associated with a worsened functional state of the patient, which can be used as an indicator for the inclusion of more intensive pulmonary rehabilitation.[
Studies show that in kids with congenital heart defects, aerobic capacity (measured via VO2peak) decreases four times faster compared to healthy controls.[
Despite the increase in the applicability of CPET in pediatric populations, several challenges remain. A major limitation is the lack of comprehensive pediatric reference values for many of the CPET parameters. Existing data is often derived from small studies with a limited number of children and thus may not always account for differences in age, sex, body composition, and levels of physical training.[
Furthermore, the lack of standardized pediatric protocols presents a challenge when choosing the right ergometer and exercise load for pediatric patients. Variations in protocol design, workload increments, and test duration limit the comparability of studies.[
The implementation of contemporary technologies such as machine learning and artificial intelligence (AI) may influence the way in which CPET data is interpreted.[
CPET represents a valuable and increasingly utilized tool for assessment of the integration between cardiovascular, respiratory, and metabolic responses to exercise in children. By providing an objective measurement of the functional capacity, as well as identifying exercise-limiting factors, CPET plays an important role in evaluating children with suspected cardiopulmonary diseases, as well as in the assessment of exercise performance of young athletes. However, challenges regarding reference values and standardized protocols remain. Results interpretation may be influenced by growth-related physiological variability and sport-specific adaptations. Future studies should focus on establishing normative datasets and improving methodological standardization, as well as focus on the implementations of submaximal parameters in the pediatric population.
The authors have no support to report.
The authors have declared that no competing interests exist.
The authors accept full responsibility for the content of the manuscript, including the disclosure of any use of AI. The following AI tools were used in the preparation of this manuscript: GPT. GPT was used for the purposes of improving language, refining writing style, assisting in literature discovery, and brainstorming.
No funding was reported.
Author contributions
Both authors have contributed equally to the preparation of this manuscript. They have approved the contents of this manuscript and agree with its submission to Folia Medica.
Blagoy Marinov https://orcid.org/0000-0001-9640-1906
All data used are referenced or included in the article.