Original Article |
Corresponding author: Zlatina Tomova ( zlatina_tomova@abv.bg ) © 2023 Zlatina Tomova, Atanas Chonin, Iliyana Stoeva, Angelina Vlahova.
This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation:
Tomova Z, Chonin A, Stoeva I, Vlahova A (2023) Clinical and laboratory study of corrosion resistance of a base dental alloy for selective laser melting. Folia Medica 65(4): 664-670. https://doi.org/10.3897/folmed.65.e73531
|
Introduction: CAD/CAM technologies are becoming widely used for the production of metal ceramic dental restorations. Powder Co-based alloys are developed for selective laser melting. The corrosion resistance of the dental alloy affects the biocompatibility, functional suitability, and longevity of the prosthetic restoration.
Aim: The aim of this study was to evaluate and compare the corrosion resistance of a cobalt-chromium dental alloy for porcelain-fused-to-metal (PFM) crowns produced for selective laser melting technique in clinical and laboratory conditions.
Materials and methods: PFM crowns were made for 35 patients using CAD/CAM technology. The metal copings of the crowns were made of the EOS CobaltChrome SP2 alloy (EOS, Germany). Eocp measurements were conducted 2 hours and 7 days after fixing the restorations in oral cavity. The digital files of patients’ designed copings were used for the production of another 35 specimens, which were placed in artificial saliva. Eocp measurements were conducted after the same periods.
Results: In vitro studies showed high corrosion resistance after the short 2-hour stay. After 7 days in artificial saliva, the corrosion resistance became even higher probably due to strong passivation. In clinical conditions, Eocp values were slightly higher than the normal range 2 hours after fixing the crowns. Seven days after fixing, the Eocp values showed a decrease of corrosion resistance of the PFM crowns. The cause of the decrease may be interaction with other metal objects or specific conditions of the oral cavity.
Conclusions: The investigated alloy showed high corrosion resistance in in vitro settings. Clinical research revealed that PFM crowns had lower corrosion resistance. Further observation and research are required.
cobalt based alloys, corrosion resistance, SLM
Metal-ceramic restorations are fabricated using either the traditional lost-wax method or cutting-edge CAD/CAM techniques. There are two main ways to create the metal copings when using modern digital techniques: milling or 3D printing by selective laser melting (SLM). These two methods provide fast and precise dental restorations.[
Structural, mechanical properties, marginal fit, metal ceramic bond strength, and corrosion resistance depend on the composition of the alloy and the fabrication method of the metal copings.[
Corrosion resistance of dental alloys is critical for the biocompatibility and has a direct impact on the functional suitability and longevity of prosthetic restorations.[
The oral cavity contains a thin biofilm composed of proteins and glycoproteins from saliva. After fixing a prosthetic restoration in the patient’s mouth, this organic layer covers its surface, potentially reducing corrosion. Despite the formation of a passive oxide layer and the presence of biofilm, it is possible that metal objects in the oral cavity will continue to corrode.[
The aim of this study was to determine the corrosion resistance of a cobalt-chromium dental alloy produced for selective laser melting technique in clinical and laboratory environment.
Porcelain-fused-to-metal crowns were manufactured for 35 patients using CAD/CAM technology. After taking digital impressions (Fig.
Informed consent was obtained from all patients included in the study. None of the patients reported symptoms of gastric disorders and no signs of acidic erosion on the hard dental tissues were observed. The crowns were fixed with resin-modified glass ionomer cement Ketac Cem Plus (3M ESPE, USA) (Fig.
The tests were conducted in the morning. Before the measurements, patients were instructed not to consume any food or drink other than water. The corrosion resistance of the alloy in clinical conditions was assessed according to the values of the open circuit potentials (Еocp) appearing between the visible metal edge of the PFM crown and the gingiva at a distance of 2-4 mm using a Dentotest Six apparatus (Atlantis, Bulgaria). The apparatus was calibrated with a voltage calibrator FLUKE SLK 753 and was approved by the standard ISO 13485 (CE 2274). The measurements were conducted 2 hours after fixing the crowns into the patients’ oral cavities and after a period of 7 days.
For the in vitro measurements, the patients’ digital files of the designed copings were used and another 35 metal specimens were produced from the same alloy using SLM and 3D printing. After selective laser melting and stress-relieving regime, the specimens were sandblasted with 50-μm Al2O3 particles. The metal copings were immersed in artificial saliva (Fig.
For statistical analysis, SPSS v. 19.0 was used, applying the parametric independent sample t-test and the paired sample t-test.
The results of the open circuit potential measurements of the specimens placed in artificial saliva and the Eocp values received from the crowns in the oral cavity are presented in Table
Two hours after placing the metal copings in artificial saliva with pH of 7.4±0.1, the Eocp measurements were within the accepted range. There was no statistically significant difference between the received values and the norm of −150 mV.
After staying 7 days in artificial saliva, the Eocp values were also within the accepted range and were significantly lower (in absolute values) than the Eocp values received after the 2-hour stay (Fig.
Two hours after fixing the PFM crowns in the oral cavity, 19 of the crowns (54.3%) had higher than 150 mV Eocp values. The mean was −166.6±61.2 which is insignificantly higher than the norm of −150 mV (p=0.119).
After staying 7 days in the mouth, an increase of the corrosion potential mid values was detected, but it was not significantly higher than the values measured after a 2-hour stay (p=0.149) (Fig.
Descriptive analysis of the Eocp values measured in artificial saliva (AS) and in the oral cavity (OC) (mV)
Duration of stay | min | mean | max | Standard deviation | |
AS | 2 hours | −188.00 | −114.80 | −23.00 | 49.00648 |
7 days | −135.00 | −57.54 | −13.00 | 26.78 | |
OC | 2 hours | −68 | −166.6 | −280 | 61.2 |
7 days | −23 | −188.7 | −410 | 83.3 |
. Crosstabulation: Eocp values after a 2-hour stay in oral cavity/Eocp values after a 7-day stay in the oral cavity
Eocp within normal range N | 7 days after fixing | Total crowns N (%) | p-value | ||
Eocp above normal range N | |||||
2 hours after fixing | Eocp within the normal range | 8 | 8 | 16 (45.7) | 0.090 |
Eocp above normal range | 4 | 15 | 19 (54.3) | ||
Total crowns N (%) | 12 (34.3) | 23 (65.7) | 35 (100.0) |
the in vitro studies have shown high corrosion resistance of the alloy 2 hours after placing the copings in artificial saliva. The formation of a passive layer on the metal surface provides good corrosion stability even after this short period of time. After 7 days, the resistance to corrosion becomes even higher probably due to continuing passivation or due to the stable oxide layer.
Regarding the results in clinical conditions, it can be concluded that two hours after being placed in the patient’s mouth, the PFM restoration with a substructure of the studied alloy had low corrosion resistance; furthermore, the Eocp values were close to the risky −150 mV. A one-week period was not enough for passivating the alloy surface and improving its corrosion resistance. It can be assumed that during the studied period, ion emission is high and the biocompatibility of the restoration is under consideration. The passivation process of the metal surface and the formation of a biofilm are not strong enough to improve the corrosion resistance of the alloy within the first 7 days in the mouth.
The differences between the clinical and laboratory results may be explained with the specific conditions in the oral cavity including the variable pH, temperature, and masticatory pressure. The presence of microorganisms in the oral cavity, Streptococcus mutans and Candida albicans, has a negative effect on the corrosion resistance.[
The obtained results suggest that the Cobalt-Chromium alloy EOS SP2 (EOS, Germany) has a higher corrosion resistance in the laboratory settings than in the oral environment.
This study is funded by grant No. 1/2020 of the Medical University of Plovdiv, Bulgaria.
The authors have declared that no competing interests exist.